摘要
This paper reports our successful research work of raising volume load of a small-scalesteam evaporator by adopting vertical structure instead of horizontal structure. The twophase flow (steam and hot water) entry structure and the way of water droplets separatingfrom steam were discussed. A lamp type hood entry and a new efficient separator made ofstainless steel wire mesh were suggested. The new designed evaporator operated in
This paper reports our successful research work of raising volume load of a small-scalesteam evaporator by adopting vertical structure instead of horizontal structure. The twophase flow (steam and hot water) entry structure and the way of water droplets separatingfrom steam were discussed. A lamp type hood entry and a new efficient separator made ofstainless steel wire mesh were suggested. The new designed evaporator operated in goodcondition
出处
《工程热物理学报》
EI
CAS
CSCD
北大核心
1998年第1期25-27,共3页
Journal of Engineering Thermophysics
基金
1994年广东省自然科学基金