期刊文献+

“多元素——多残留”检测在水质评价上的应用

Application of Systematic Monitoring of "Multi-element, High Residue Pollutant" in Water Quality Evaluation
下载PDF
导出
摘要 “多元素——多残留”是利用等离子体发射光谱仪(ICP-AES)和气相色谱仪(GC)联合检测水中无机元素和农药残留的方法。灵敏度高,ICP-AES的平均回收率为96.3±4.4%,变异系数为3.15±0.12%,GC的平均回收率为95.1±1.55%,变异系数为3.22±0.21%。为水质检测、环境质量定位动态监测等提供了一种高效、快速、全面的新方法。 Systematically monitoring of Multi-inorganic and organic pollutant from pesticide residue in water simultaneously by using Inductivity Coupled Plasma Atom Emission Spectrospector (ICP-AES) and Gas Chromatography (GC) is reviewed in this paper. The average recovery of ICP-AES is 96.3±4.4%, RSD is 3.15±0.12% and 95.1±1.55%, 3.22±0.29% of GC respectively. This is a new effective and rapid method with high sensitivity when applied in water quality determination and environmental evaluation.
作者 潘军 楼小华
机构地区 中国水稻研究所
出处 《环境污染与防治》 CAS CSSCI CSCD 北大核心 1990年第2期32-34,共3页 Environmental Pollution & Control
  • 相关文献

参考文献1

  • 1楼小华,梁天锡.59种农药残留量的毛细管气相色谱系统分析[J]环境化学,1989(03). 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;