期刊文献+

纳米F-PbO2修饰电极测定化学需氧量的应用研究 被引量:1

A Research on Application of Nano F-PbO2 Modified Electrode in Determination of COD
下载PDF
导出
摘要 以制备的纳米F-PbO2修饰电极为工作电极,利用安培检测法测定水体中的COD值。该电极能够催化氧化水体中的有机物,根据氧化电流的大小可以对水样的COD值进行定量,在COD值为20-500mg/L的范围内,电极的氧化电流与水样的COD值成正比。检测限为10mg/L。该电极用于实际水样的检测,耗时短。方法简单,样品无需预处理,环境友好,测定结果与国家标准分析法比对,有较好的相关性。 Abstract A nano F-PbO2 modified electrode was prepared. An electrochemical detection system with this modified electrode to determine chemical oxygen demand (COD) was proposed and experimentally validated. The measuring principle was based on the current response of the modified electrode proportional to COD value. Under an optimum condition, the application range was 20-500mg/L of COD, and the detection limit was 10mg/L. This method has been successfully applied to determine real samples without need of pretreatment, and was less time consumable, simple and environmentally friendly. In addition, this method showed excellent correlation with values obtained by using relevant conventional methods.
出处 《上海环境科学》 CAS CSCD 2005年第4期153-155,159,共4页 Shanghai Environmental Sciences
基金 国家自然科学基金,编号:20327001
关键词 化学需氧量 氟掺杂纳米PbO2修饰电极 安培检测法 Chemistry oxygen demand (COD) Nano F-PbO2 modified electrode Amperometry
  • 相关文献

参考文献8

  • 1[1]Cuesta A, Todoli J L, Mora J, et al. Rapid determination of chemical oxygen demand by a semi automated method based on microwave sample digestion,chromiun (Ⅵ) organic solvent extraction and flame atomic absorption spectrometry. Anal chim Acta, 1998,114:81~88. 被引量:1
  • 2[2]国家环保局编.水和污水监测分析方法.第三版,北京:中国环境出版社,1998,354~357. 被引量:1
  • 3[4]Korenaga T, Zhou X J, Okada K, et al. Determination of chemical oxygen demand by a flow-injection method using cerium (Ⅳ) sulphate as oxidizing agent.Anal chim Acta, 1993, 272:237~ 244. 被引量:1
  • 4[5]Jirka A M, Smith M J. Micro semiautomated analysis of surface and waste waters for chemical oxygen demand. Anal Chem, 1975,47:1397~ 1402. 被引量:1
  • 5[6]Canals A, Cuesta A, Gras L, et al. New ultrasound assisted chemical oxygen demand determination. Ultra Sonochem, 2002, 9:143 ~ 149. 被引量:1
  • 6艾仕云,李嘉庆,杨娅,柴怡浩,孙郑冬,金利通.一种新的光催化氧化体系用于化学需氧量的测定研究[J].高等学校化学学报,2004,25(5):823-826. 被引量:26
  • 7[8]Li B X, Zhang Z J, Wang J, et al. Chemiluminescence system for automatic determination of chemical oxygen demand using flow injection analysis. Talanta,2003, 61:651 ~ 658. 被引量:1
  • 8[9]Kim Y, Lee K, Sasaki S, et al. Photocatalytic Sensor for Chemical Oxygen Demand Determination Based on Oxygen Electrode. Anal Chem, 2000, 72:3379~3382. 被引量:1

二级参考文献14

  • 1Josef H., Jiri K.. Analyst[J], 1990, 115: 1 463-1 467 被引量:2
  • 2Compile Committee of ''Analytical Methods Guide for the Examination of Water and Wastewater''(水和废水检测分析方法指南编委会). Analytical Methods Guide for the Examination of Water and Wastewater(水和废水监测分析方法指南 被引量:1
  • 3Legrini O., Oliveros E., Braun A. M.. Chem. Rev.[J], 1993, 93: 671-698 被引量:2
  • 4Hoffmann M. R., Martin S. T., Choi W. et al.. Chem. Rev.[J], 1995, 95: 69-96 被引量:1
  • 5Bandara J., Tennakone K., Jayatilaka P. P. B.. Chemosphere[J], 2002, 49: 439-445 被引量:1
  • 6Paola A. D., Augugliaro V., Palmisano L. et al.. J. Photochem. Photobiol. A: Chem.[J], 2003, 155: 207-214 被引量:1
  • 7Japanese Industrial Standard Committee. Testing Methods for Industrial Waste Water[M], JIS K 0102, JIS, Tokyo, 1993 被引量:1
  • 8Emmanuel T., Anthony E. G. C., Brian O. et al.. J. Electroanal. Chem.[J], 2001, 517: 20-27 被引量:1
  • 9Borgarello E., Harris R., Serpone N. N.. J. Chem.[J], 1985, 9: 743-747 被引量:1
  • 10Himebaugh R. R., Smith M. J.. Anal. Chem.[J], 1979, 51(7): 1 085-1 087 被引量:1