摘要
应用等效热降理论,定量分析了邹县电厂DH-600-40-T型机组回热加热器散热损失对机组热经济性的影响,分析数据表明,应采取有力措施,减少加热器的散热损失,并特别做好№1、№2高压加热器的保温隔热工作。
This Artical Quantitatively Analyzes the Influence of Regenerative Heater Heat Release on Heat Economy of the DH-600-40-T Unit in Zouxian Power Plant by Using the Equivalent Heat Drop Theory.The Analysis of Vibration Data Shows That Strong Measures Should be Adopted to Reduce the Regenerative Heater Heat Release and Particularly Do Heat Preservation and Heat Insulation on HP Heater 1 and HP Heater 2 Good as well.
出处
《山东电力技术》
1997年第6期21-23,共3页
Shandong Electric Power