摘要
针对脉冲式分线制远传抄表技术应用现状,分析其存在的问题和风险,提出相应的对策措施。介绍了直读式总线制远传抄表技术的原理、特点、系统组成与运行方式、主要技术参数、通信方式,比较了直读式总线制远传抄表技术与脉冲式分线制远传抄表技术的特点,介绍了直读式总线制远传抄表技术的应用试验效果,提出了发展远传抄表技术的思路。
Based on the present application status of remote meter reading technology with pulsetype separate system, its problems and risk are analyzed, and the relevant countermeasures are put forward. The principle and characteristics of remote meter reading technology with direct reading-type bus system, the system composition and operation mode, the main technical parameters and the communication mode are introduced. The characteristics of above mentioned two technologies are compared. The application test results of remote meter reading technology with direct reading-type bus system are presented, and the idea for developing the remote meter reading technology is proposed.
出处
《煤气与热力》
2008年第11期40-43,共4页
Gas & Heat
关键词
脉冲式
直读式
远传抄表技术
pulse-type
direct reading-type
remote meter reading technology