期刊文献+

土壤源空调系统全年运行设计与计算分析 被引量:2

DESIGN AND ANALYSIS OF THE ANNUAL RUNNING OF GROUND SOURCE HEAT PUMP SYSTEM
下载PDF
导出
摘要 采用贝塞尔函数求解了U型埋地换热器在稳态和正弦波边界下的解析解,可计算给定全年动态负荷下埋地换热器内流体温度,并据此判断埋地换热器的设计能否满足建筑物的要求。给出了在不同因素影响下流体全年最高温度和最低温度与U型管单位长度设计取冷(热)量的关系曲线,可用于指导U型埋地换热器的设计。得到了建筑物全年累计耗热量和耗冷量、最大热负荷和冷负荷应满足的关系,可用于指导建筑物冷热源方案的搭配。 Ground source heat pump system has been developed quickly in recent years for its low operating costs and no contaminant. The design of geothermal heat exchangers and the annual heat balance problem is the most important and difficult problem in ground source heat pump system. Bessel function was used to establish heat transfer model of U shape buried pipe of geothermal heat exchangers under harmonic and steady boundary conditions. The annual fluid temperature in U shape pipe can be computed using the heat transfer model when annual heating or cooling load is known. The curves are computed showing how maximum and minimum fluid temperature varies with the unit length design load of U shape pipe. The curves can be used to design U shape pipe. The annual total heating and cooling energy, the peak heating and cooling load should meets some conditions to assure the ground source heat pump system run well. The conditions were studied and could be used to design the heating and cooling source in a building.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2008年第10期1218-1224,共7页 Acta Energiae Solaris Sinica
关键词 土壤源系统 U型埋地换热器 传热模型 全年热平衡 ground source heat pump system U shape buried pipe of geothermal heat exchangers heat transfer model armual heat balance
  • 相关文献

参考文献11

  • 1王勇,刘宪英,付祥钊.地源热泵及地下蓄能系统的实验研究[J].暖通空调,2003,33(5):21-23. 被引量:20
  • 2孙恒虎,崔建强,毛信理.地源热泵的节能机理[J].太阳能学报,2004,25(1):24-27. 被引量:20
  • 3Mei V C, Emerson C J. New approach for analysis of groundcoil design for applied heat pump systems [ J ]. ASHRAE Transaction, 1985, 91(2): 1216--1224. 被引量:1
  • 4Rottmayer S P, Beckman W A, Mitchell J W. Simulation of a single vertical U-tube ground heat exchanger in an infinite medium[J]. ASHRAE Transactions, 1997, 103(2): 651-- 659. 被引量:1
  • 5Muraya N K, O'Neal D L, Heffington W M. Thermal interference of adjacent legs in vertical U-tube heat exchanger for a grotmd-coupled heat pump [ J ]. ASHRAE Transactions, 1996, 102(2): 12--21. 被引量:1
  • 6Yavuzturk C, Spider J D, Rees S J. A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers[ J]. ASHRAE Transactions, 1999, 105(2) : 465--474. 被引量:1
  • 7Deerman J D, Kavanaugh S P. Simulation of vertical U-tube ground-coupled heat pump systems using the cylindrical heat source solution[J]. ASHRAE Transactions, 1991, 97(1): 287--294. 被引量:1
  • 8Michel A B. Ground-coupled heat pump system simulation [A]. ASHRAE 2001 Winter Meeting CD, Technical and Symposium Papers[ C], 2001, AT-01-8-3. 被引量:1
  • 9查普曼(著),何用梅(译).传热学IM].北京:冶金工业出版社,1984. 被引量:1
  • 10彦启森,赵庆珠编..建筑热过程[M].北京:中国建筑工业出版社,1986:188.

二级参考文献16

  • 1丁勇 刘宪英 胡鸣明 等.地源热泵系统实验研究综述[A]..见:现代空调丛书:第3辑[C].北京:中国建筑工业出版社,2001.11-13. 被引量:1
  • 2Hu Mingming,Liu Xianying Experimental research on shallow coaxial tube ground-coupled heat pump for heating winter and cooling summer.In:Air conditioning in high rise bulldings’2000(ACHRB 2000).北京:中国建筑工业出版社,2000.284—289. 被引量:1
  • 3魏唐棣 胡鸣明 刘宪英.地源热泵地下埋管换热器的研究介绍[J].中国冷冻空调杂志,1999,(47):91-91. 被引量:2
  • 4刘宪英 胡鸣明.浅埋竖管换热器的地热源热泵冬季供热试验研究[J].中国学术期刊文摘,1999,5(8):1061-1062. 被引量:1
  • 5王勇 付祥钊 刘宪英.地源热泵地下管群换热器设计、施工的有关问题讨论[A]..1999年西南地区暖通制冷学术年会论文集[C].成都:西南交通大学出版社,1999.263-269. 被引量:1
  • 6何雪冰 丁勇 刘晓东.地热源热泵冬夏暖冷联供试验研究[J].冷冻与空调,2000,(3):175-175. 被引量:1
  • 7刘宪英 陈建苹 胡鸣明.地热源热泵地下竖埋套管式换热器传热模型[A]..全国暖通空调制冷2000年学术年会文集[C].北京:中国建筑工业出版社,2000.153-159. 被引量:2
  • 8何雪冰 王文 刘宪英.地热源热泵冬夏暖冷联供试验[A]..全国暖通空调制冷2000年学术年会论文集[C].,2000.501-505. 被引量:3
  • 9肖益民 何雪冰 刘宪英.地源热泵空调系统的设计施工方法及应用实例[A]..现代空调丛书:第3辑[C].北京:中国建筑工业出版社,2001.88-101. 被引量:1
  • 10蒋能照.空调用热泵技术及应用[M].北京:机械工业出版社,1998.. 被引量:2

共引文献36

同被引文献7

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部