120K温区混合工质采用带预冷的分凝循环林德制冷机的实验研究 被引量:1

Experimental research on mixed-refrigerant of using segregation Linder refrigerator with pre-cooling cycle at 120K temperature range
下载PDF
导出
摘要 提出了利用带预冷的分凝循环林德制冷系统获得了120 K温区的制冷方案。建立了实验装置,进行了不同配比的三元混合工质(R23/R14/R740)的制冷循环的性能实验。实验结果表明:三元混合工质(R23/R14/R740)较好的配比为:0.63:0.28:0.09,在无热负荷时,制冷温度为123 K时,降温时间为3 h。 The thermodynamic process for obtaining the 120 K temperature range was proposed based on the mixed-refrigerant using segregation Linder refrigerator with pre-cooling cycle . The experiment set-up was established. The system performances were investigated under different composition of ternary refrigerant(R23/R14/R740). The experiment results showed that the best ratio of ternary refrigerant (R23/R14/ R740) was 0. 63 :0. 28 :0. 09,the refrigerating temperature without heat loads was 123 K and the cool-down time was 3 h.
出处 《低温工程》 CAS CSCD 北大核心 2008年第5期45-48,共4页 Cryogenics
关键词 分凝循环 混合工质 林德制冷机 实验研究 segregation cycle mixed-refrigerant Linder refrigerator experimental research