期刊文献+

三维MRA技术在肝脏血管成像中的应用研究

Study of 3D ceMRA technique of Hepatic Vessels
原文传递
导出
摘要 目的:探讨三维增强MRA(3Dc eMRA)技术在肝脏磁共振血管成像中的应用价值。方法:52例行肝脏磁共振血管成像患者及30例对照组病人,利用自动透视触发技术进行肝脏血管成像,造影剂到达降主动脉起始段时启动3D扫描,扫描时相包括肝动脉期、门静脉期及腔静脉期,分离各组图像并与蒙片剪影,再进行最大信号强度投影(MIP)及多平面图像重建(MPR),评价各期图像质量。结果:采用3Dc eMRA技术所获肝动脉期及门静脉期图像质量满意;造影剂到达降主动脉起始段时间与造影剂流速、总量之间呈线性相关;造影剂总量和流速与肝血管信号强度呈正相关。结论:3Dc eMRA技术可准确把握造影剂到达靶血管时间,结合最佳的造影剂总量和注射速度,明显提高肝脏磁共振血管成像质量。 Objective: To investigate the clinical value of 3D eeMRA of hepatic vessels.Method: 3D ceMRA was performed in 82cases.When contrast arrived descending aorta, 3D scan started.Artery phase、portal vein phase, vena cava phase were acquired.The images were subtracted and reconstructed by MIP or MPR.The quality of image was evaluated. Results: With this technique high quality of images were obtained. Contrast volumes and flow rate correlated with the time when bolus reached the target vessel. And contrast volume and flow rate have linearity correlation with the signal of hepatic vessel. Conclusion: 3D ceMRA technique can grasp the exact time when contrast reached target vessel. Combined with best contrast volume and flow rate, can improve the image quality obviously.
出处 《福州总医院学报》 2008年第3期206-210,共5页 Journal of Fuzhou General Hospital
关键词 肝脏 血管 磁共振成像 增强 三维重建 Liver Vessel MRI Enhancement 3Dreconstruction
  • 相关文献

参考文献4

  • 1张照喜,陈宪,徐宁,刘玉林,郑之青,蒋春林.iPass技术在腹部3D-CE-MRA中的应用[J].放射学实践,2005,20(1):77-80. 被引量:6
  • 2方佳,贾宁,吴晓明,冯祥太,汤艳萍,宋发亮,郭佑民.动态增强MRA在胸腹部大血管成像中的应用[J].实用放射学杂志,2004,20(9):854-855. 被引量:7
  • 3Moon-Gyu Lee M.D.,Kwang Bo Park M.D.,Yong Moon Shin M.D.,Hyun Ki Yoon M.D.,Kyu Bo Sung M.D.,Myung Hwan Kim M.D.,Sung Gyu Lee M.D.,Eun Mee Kang Ph.D.. Preoperative Evaluation of Hilar Cholangiocarcinoma with Contrast-enhanced Three-dimensional Fast Imaging with Steady-state Precession Magnetic Resonance Angiography: Comparison with Intraarterial Digital Subtraction Angiography[J] 2003,World Journal of Surgery(3):278~283 被引量:1
  • 4Stephen J. Riederer,Sean B. Fain,David G. Kruger,Reed F. Busse. Real-time imaging and triggering of 3D contrast-enhanced MR angiograms using MR fluoroscopy[J] 1999,Magma: Magnetic Resonance Materials in Physics, Biology, and Medicine(3):196~206 被引量:1

二级参考文献15

  • 1Earls JP,Rofsky NM,Decorato DR,et al. Breath-hold Single-dose Gadolinium-enhanced Three-dimensional MR Aortography: Usefulness of a Timing Examination and MR Power Injector[J]. Radiology , 1996,201 (3): 705-710. 被引量:1
  • 2Foo TK,Saranathan M,Prince MR,et al. Automated Detection of Bolus Arrival and Initiation of Data Acquisition in Fast,Three-dimensional,Gadolinium-enhanced MR Angiography[J]. Radiology,1997,203(1) :275-280. 被引量:1
  • 3Prince MR,Narasimham DL,Stanley JC,et al. Breath-hold Gadolinium-enhanced MR Angiography of the Abdominal Aorta and its major Branches[J]. Radiology, 1995,197(3): 785-792. 被引量:1
  • 4Maki JH,Prince MR, Londy FJ,et al. The Effects of Time Varying Intravascular Signal Intensity and K-Space Acquisition Order on Three-Dimensional MR Angiography Image Quality [J]. J Magn Reson Imaging,1996,6(4):642-651. 被引量:1
  • 5Riederer SJ, Bernstein MA, Breen JF, et al. Three-dimensional Contrast-enhanced MR Angiography with Real-time Fluoroscopic Triggering:Design Specifications and Technical Reliability in 330Patient Studies[J]. Radiology,2000,215(2) :584-593. 被引量:1
  • 6Lee JJ,Tirman PJ,Chang Y, et al. The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography[J].Korean J Radiol, 2000,1(3): 142-151. 被引量:1
  • 7Prince MR,Chenevert TL,Foo TK, et al. Contrast-enhanced Abdominal MR Angiography:Optimization of Imaging Delay Time by Automating the Detection of Contrast Material Arrival in the Aorta[J]. Radiology, 1997,203(1): 109-114, 被引量:1
  • 8Lentschig MG, Reimer P, Rausch-Lentschig UL, et al. BreathHold Gadolinium-Enhanced MR Angiography of the Major Vessels at 1.0T Dose-response Findings and Angiography[J]. Radiology, 1998,208(2): 353-357. 被引量:1
  • 9Hany TF, Debation JF, Leung DA, et al. Optimization of Contrast Timing for Breath-hold Three-dimensional MR Angiography[J]. Radiology,1997,204(5) :357-362. 被引量:1
  • 10Ho VB,Foo TK. Optimization of Gadolinium-Enhanced Magnetic Resonance Angiography Using an Automated Bolus-Detection Algorithm (MR SmartPrep) Original Investigation [J]. Invest Radiol,1998,33(9) :515-523. 被引量:1

共引文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部