摘要 目的探讨双源CT能量减影法CTA在脑动脉瘤诊断中的应用价值。方法43例39个动脉瘤使用双源CT双能量扫描,分别进行能量减影法CTA重建(A法)和模拟常规CTA重建(B法)。比较两种方法的动脉瘤检出率和动脉瘤颈、瘤体显示评分。结果A法检出率为100%;B法检出率为97.4%,(P>0.05)。动脉瘤颈显示评分:A法与B法均是Ⅲ级37个,Ⅱ级2个;动脉瘤体显示评分:A法与B法均是Ⅲ级35个,Ⅱ级4个。两法在瘤颈、瘤体观察评分上无差异。结论双能量减影CTA,自动去除颅底骨干扰,节省后处理时间,在动脉瘤检出及瘤颈、瘤体显示上达到常规CTA同样效果。 Objective To explore the useful value of energy subtract angiography in diagnosis of cerebral aneurysms using dual source CT (DSCT). Methods Forty-three patients with 39 aneurysms underwent DSCT dual energy scan. Raw data were reconstructed with dual energy subtract method (A) and conventionally simulated method (B), respectively. Detection rate of aneurysm and display score of aneurysm neck and body between two methods were compared, respectively. Results The detection rate in method A and B were 100% and 97.4%, respectively (P〉0.05). The display scores of aneurysm neck were III level 37, II level 2 in both method A and B. The display score of aneurysm body were III level 35, II level 4 in both method A and B. Statistically no differences in display score of aneurysm neck and body were showed between method A and method B. Conclusion Dual energy subtract CT angiography makes post-processing time saved by automatically removing disturbance of basic skull and also reaches the same satisfactory result in the detection rate of aneurysm and display of the neck and body of aneurysm compared with conventionally simulated CTA.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第9期1319-1322,共4页 Chinese Journal of Medical Imaging Technology
关键词 颅内动脉瘤 体层摄影术 X线计算机 Intracranial aneurysm Tomography, X-ray computed
  • 相关文献

参考文献8

  • 1Chen CJ, Chen ST. Extracranial distal aneurysm of posterior inferior cerebellar artery. Neuroradiology, 1997,39(5) :344-347. 被引量:1
  • 2Lubicz B, Levivier M, Francois O, et al. Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and intertechnique reproducibility. American Journal of Neuroradiology, 2007, 28 (2) : 1949- 1955. 被引量:1
  • 3Velthuis BK, Rinkel G J, Ramos LM, et al. Subarachnoid hemorrhage : aneurysm detection and preoperative evaluation with CT angiography. Radiol, 1998,208(2):423-430. 被引量:1
  • 4Lubicz B, Levivier B, Franois O, et al. Sixty-four-row multisection CT angiography for detection and evaluation of ruptured intracranial aneurysms: interobserver and interteehnique reproducibility. American Journal of Neuroradiology, 2007, 28 (10) : 1949- 1955. 被引量:1
  • 5Korogi Y, Takahashi M, Katada K, et al. Intracranial aneurysms: detection with three-dimensional CT angiography with volume rendering-comparison with conventional angiographie and surgical findings. Radiology, 1999,211(2):497-506. 被引量:1
  • 6Fishman EK, Ney DR, Heath DG, et al. Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why? RadioGraphics, 2006,26 (3) : 905-922. 被引量:1
  • 7Flohr TG, Stierstorfer K, Ulzheimer S, et al. Image reconstruction and image quality evaluation for a 64-slice CT scanner with zfly-ing focal spot. Med Phys, 2005,32(8) : 2536-2547. 被引量:1
  • 8张宗军,卢光明.双源CT原理与临床应用[J].医疗卫生装备,2007,28(10):57-58. 被引量:38

二级参考文献8

  • 1Flohr T G, McCollough C H, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system [J]. Eur Radiol, 2006, 16:256-268. 被引量:1
  • 2Flohr T G, Stierstorfer K, Ulzheimer S, et al. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot[J]. Med Phys, 2005, 32:2536-2547. 被引量:1
  • 3Raff G L, Gallagher M J, O'Neill W W, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography [J]. J Am Coll Cardiol, 2005, 46:552-557. 被引量:1
  • 4Flohr T G, Schaller S, Stierstorfer K, et al. Multi-detector row CT systems and image-reconstruction techniques [J]. Radiology, 2005, 235:756-773. 被引量:1
  • 5Achenbach S, Ropers D, Kuettner A, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience [J]. Eur J Radiol, 2006, 57:331-335. 被引量:1
  • 6Wintersperger B J, Nikolaou K, van Ziegler F, et al. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed [J]. Invest Radiol, 2006, 41:436-442. 被引量:1
  • 7Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J]. Eur Radiol,2006,16:2739- 2747. 被引量:1
  • 8Johnson T R, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: initial experience[J]. Eur Radiol,2007,17:1510- 1517. 被引量:1

共引文献37

同被引文献76

  • 1李忠凯,李力,张丽波,王甦.CT-A血管成像在颈部血管病中的诊断价值[J].CT理论与应用研究(中英文),2006,15(2):60-63. 被引量:2
  • 2张杨,李彩霞.三维数字血管造影在颅内动脉瘤诊治中的应用[J].中国介入影像与治疗学,2007,4(1):35-38. 被引量:5
  • 3吕发金,谢鹏,罗天友,张志伟,何怡红,孙晓川,牟君,方维东.数字减影CT血管成像在蛛网膜下腔出血诊断中的价值[J].中国医学影像技术,2007,23(1):45-48. 被引量:114
  • 4Nakayama Y,Awai K,Funama Y,et al.Abdominal CT with low tube voltage:preliminary observations about radiation dose,contrast enhancement,image qulity,and noise.Radiology,2005,237(3):945-951. 被引量:1
  • 5Johnson TR,Krauss B,Sedlmair M,et al.Material differentiation by dual energy CT:initial experience.Eur Radiol,2007,17(6):1510-1517. 被引量:1
  • 6Graser A,Johnson TR,Bader M,et al.Dual energy CT characterization of urinary calculi:initial in vitro and clinical experience.Invest Radiol,2008,43(2):112-119. 被引量:1
  • 7Jayaraman MV,Mayo-Smith WW,Tung GA,et al.Detection of intracranial aneurysms:multi-detector row CT angiography compared with DSA.Radiology,2004,230(2):510-518. 被引量:1
  • 8Fishman EK,Ney DR,Heath DG,et al.Volume rendering versus Maximum intensity projection in CT angiography:what works best,when,and why.Radiographic,2006,26(3):905-922. 被引量:1
  • 9Tomandl BF,Kostner NC,Schempershofe M,et al.CT angiography of intracranial aneurysms:a focus on postprocessing.Radiographic,2004,24(3):637-655. 被引量:1
  • 10Matsumoto M,Kasuya H,Sato T,et al.Can 3D-CT angiography (3D-CTA) replace conventional catheter angiography in ruptured aneurysm surgery? Our experience with 162 cases.Fukushima J Med Sci,2007,53(2):85-94. 被引量:1