介绍冷却塔进行节能供冷的工作过程,通过对工程实例中发现的一些问题进行分析,提出利用开式冷却塔加板式热交换器并联于制冷机的冬季供冷系统是较经济实用的形式,且必须同时注意冷却塔冬季的热工曲线、冷却塔供冷与制冷机供冷工况切换、冷水机组配置、冷却水系统水处理问题等。
To introduce the procedures of cooling tower in cooling for encrgy saving. By means of analyzing some problems found in projects, chiller paralleled with plate heat exchanger system is a comparatively economical and practical way to get cooling by cooling tower. In the mean time, pay attention to the cooling tower performance curve in winter, the performance change between plate heat exchanger and the chiller, the disposal of chiller assembly and condenser water treatment etc.
出处
《洁净与空调技术》
2008年第3期48-51,55,共5页
Contamination Control & Air-Conditioning Technology
关键词
冷却塔供冷
经济性
冷却塔冬季热工曲线
工况切换
水处理
cooling tower cooling
economical
cooling tower performance curve
performance change