通过定点实测探讨了庭院内和周边外部环境的关系,测量数据表明,庭院式建筑将炎热的夏季户外环境转化为相对温和的局部微环境,由此使新风能耗相对于非庭院式建筑下降了19%~30%。
The site measurement was undertaken to investigate the interaction between the courtyard and the ambient in this study. The measured dates indicate that the courtyard style building transforms a hot summer outdoor open space into a moderate micro-climate. As the result that 19%-30% of energy consumption of fresh air could be saved in the courtyard, in comparison with a no-courtyard style building.
出处
《洁净与空调技术》
2008年第3期16-20,共5页
Contamination Control & Air-Conditioning Technology
关键词
庭园式建筑
新风能耗
夏季
the courtyard style building
energy consumption of fresh air
summer School of Environmental Science and Engineering, Donghua University, Shanghai.