摘要
对华能大连电厂在应用单元机组协调控制功能中遇到的问题所采取的有效措施进行评价,指出唯采用协调控制系统,单元机组才能完成多变量控制,做到安全、稳定、经济运行。前提条件是,必须做好控制系统的设计和调试。
Some problems occurred in the coordinated control functions adopted in the generating units of Huaneng Dalian Power Plant.The effective measures taken to resolve these problems are evaluated in this article. The coordinated control system is the only way to fulfil the multi variables control and to ensure the safe, stable and economic operation of generating unit. The prerequisite is, the design and debugging of control system must be bulfilled well so as to realize the functions of coordinated control.
出处
《中国电力》
CSCD
北大核心
1997年第8期45-49,共5页
Electric Power
关键词
发电厂
单元机组
机炉协调控制
经济运行
generating unit multi variables coordinated control of boiler and turbine economic operation