摘要 目的:探讨64层VCT冠状动脉造影在冠状动脉疾病的诊断价值。方法:对198例临床怀疑为冠心病的患者,进行了64层VCT冠状动脉造影,对所有病例使用GEAW独立工作站提供的冠状动脉分析软件进行分析,主要进行了最大密度投影重建(MIP)、多平面重建(MPR)、容积重建(VR)。结果:64层VCT对冠状动脉的狭窄程度、内支架植入术后及血管搭桥术后复查进行评价。结论:64层VCT作为冠状动脉疾患的筛选、内支架术后及血管搭桥术后疗效随访有很大的临床应用价值。 Objective:To evaluate the diagnostic value of 64-row VCT coronary anglography in coronary artery disease. Methods: Sixty-four-row VCT coronary angiography was performed in 198 patients with suspercted coronary artrry disease pfivided by GE AW workstation, and some post-treatments were conducted involving MIP, MPR and VR. Results:Tile stenosis degree of coronary artery and reexamination after coronary stent implantation and vascular bypass were assessed by 64-row VCT. Conclusion: Sixty-four-row VCT has important clinical value in screening coronary artery disease and in post operational effctiveness of coronary stent implantation and vascular bypass.
机构地区 解放军
出处 《医学影像学杂志》 2008年第8期873-875,共3页 Journal of Medical Imaging
关键词 冠状动脉造影术 冠心病 体层摄影术 X线计算机 Coronary angiography Coronary artery disease Tomography, X-ray computed
  • 相关文献

参考文献4

二级参考文献24

  • 1李占全.冠状动脉分段.见:李占全,主编.冠状动脉造影与临床.沈阳:辽宁科学技术出版社,2001.76-77. 被引量:1
  • 2Nieman K,Cademartiri F,Lemos RA,et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation, 2002,106 ( 16 ) : 2051 ~ 2054. 被引量:1
  • 3Flohr TH,Stierstorfer K, Bruder H,et al. Image reconstruction and image quality evaluation for a 16 slice CT scanner. Medical Physics.2003,30(5) :832~845. 被引量:1
  • 4Achenbach S,Giesler T,Ropers D,et al. Detection of Coronary Artery Stenoses by Contrst- Enhanced, Retrospectively Electrocardiographically- Gated, Multislice Spiral Computed Tomography. Circulation,2001,103(21) :2535~2538. 被引量:1
  • 5Wang G,Vanner MW. The effect of pitch in multislice spiral/helical CT. Med Phys, 1999,26:2648~2653. 被引量:1
  • 6Sauedo JF,Popma JJ,Kennard ED,et al. Relation of coronary artery size to one- year clinical events after new device angioplasty of native coronary stenoses. Am J Cardiol, 2000,85 : 166 ~ 171. 被引量:1
  • 7Ropers D,Baum U,Pohle K,etal.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107(5):664-666. 被引量:1
  • 8Mollet NR,Cademartiri F,Nieman K,etal.Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.J Am Coll Cardiol,2004,43(12):2265-2270. 被引量:1
  • 9Martuscelli E,Romagnoli A,D'Eliseo A,etal.Accuracy of thin-slice computed tomography in the detection of coronary stenoses.Eur Heart J,2004,25(12):1043-1048. 被引量:1
  • 10Detre KM,Wright E,Murphy ML,etal.Observer agreement in evaluating coronary angiograms.Circulation,1975,52(6):979-986. 被引量:1