摘要
对张家口发电厂8号炉低温过热器受热面大面积吹损原因进行了分析,并采取了相应的措施,避免了低温过热器大面积爆管泄漏的发生,保证了锅炉的安全运行。
This paper analyzed the cause of damage with large area of heating surface of low temperature over heater of boiler 8 in Zhangjiakou Power Plant ,the respective countermeasures were adopted to refrain from occurrence of tube explosion with large area and leakage of low temperature over heater and assures safety operation of boiler.
出处
《华北电力技术》
CAS
2008年第9期34-36,共3页
North China Electric Power
关键词
锅炉
低温过热器
受热面
吹损
boiler
low temperature over heater
heating surface
damage