期刊文献+

自制气道封堵器在经支气管镜肺减容术中的应用 被引量:7

The use of a self-made airway occluder in bronchoscopic lung volume reduction
下载PDF
导出
摘要 目的探讨自制内塞式支气管封堵器在经支气管镜肺减容术(BLVR)中的应用效果。方法选择2例稳定期重度慢性阻塞性肺疾病(COPD)患者,在支气管镜引导下于靶位支气管置入1或2枚自制的镍钛合金封堵器,比较患者术前、术后7个月的肺功能、动脉血气、圣.乔治呼吸疾病问卷(SGRQ)、胸部CT及并发症等指标的差异,评价BLVR的疗效。结果置入的封堵器无一脱落或移位;局部黏膜仅见轻度肉芽组织增生;被封堵的靶位肺组织出现不张或膨胀不全。术前和术后7个月,病例1、2的静态肺容积(VC)分别从3.08L上升至3.57L,2.19L上升至2.58L;用力肺活量(FVC)分别从2.87L上升至3.57L,2.60L上升至2.58L;SGRQ调查显示患者的呼吸困难症状显著改善,分值分别从62降低至26,48降低至23;但动脉氧分压提高均不明显。2例患者均未发生阻塞性肺炎、气胸等严重并发症。结论本课题组自行研制的封堵器在两例重度COPD患者中初步应用已显示出其置入简便、稳定性好、封堵效果确实、并发症少的优点,能够达到肺减容及改善肺功能的目的。 Objective To explore the therapeutic efficacy of a self-made occluder used for bronchoscopic lung volume reduction(BLVR).Methods Two patients with severe chronic obstructive pulmonary disease(COPD)in stable phase were selected for the present study.One or two nitinol occluders were placed,guided by brochoscopy,into the target bronchi of the two patients.Examination of pulmonary functions,chest computed tomography,complications,blood gas analysis,and evaluation of life quality with St George's respiratory questionnaire(SGRQ)were carried out before and 7 months after the bronchoscopic lung volume reduction.Results No dislodging or shifting of all the inserted occluders occurred.Only slight proliferation of granulation tissue was found in mucous membrane around the occluder,and atelectasis was observed at the target sites of lung.Before and 7 months after BLVR,ventilatory capacity(VC)of case 1 rose from 3.08L to 3.57L,and that of case 2 was elevated from 2.19L to 2.58L.Forced vital capacity(FVC)of case 1 was elevated from 2.87L to 3.57L,and that of case 2 from 2.60L to 2.58L.SGRQ showed a remarkable improvement of patients' dyspnea with a decrease of scores from 62 to 26 in case 1 and from 48 to 23 in case 2.No evident changes were found on arterial oxygen blood partial pressure(PaO2)in both patients,and no severe complications such as obstructive pneumonia or pneumothorax occurred yet in either case 1 or case 2.Conclusion The present study has demonstrated that the self-made occluder is convenient for insertion with satisfactory stability and therapeutic efficacy.Application of such occluder is safe with few complications,and may serve the purpose of reducing lung volume and improving lung function.
出处 《解放军医学杂志》 CAS CSCD 北大核心 2008年第8期1012-1015,共4页 Medical Journal of Chinese People's Liberation Army
基金 第四军医大学西京医院临床高新技术课题(XJGX0512M0)
关键词 肺疾病 慢性阻塞性 经支气管镜肺减容术 封堵器 pulmonary diseases,chronic diseases bronchoscopic lung volume reduction occluder
  • 相关文献

参考文献10

  • 1Wan IY, Toma TP, Geddes DM, et al. Bronchoscopic lung volume reduction for end-stage emphysema: report on the first 98 patients. Chest, 2006, 129(3):518. 被引量:1
  • 2Ingenito EP, Berger RL, Henderson AC, et al. Bronchoscopic lung volume reduction using tissue engineering principles. Am J Respir Crit Care Med, 2003, 167(5):771. 被引量:1
  • 3Sabanathan S, Richardson J, Pieri-Davies S. Bronchoscopic lung volume reduction. J Cardiovasc Surg, 2003, 44(1) : 101. 被引量:1
  • 4Roger AM. New and emerging minimally invasive techniques for lung volume reduction. Chest, 2004, 125 (2): 777. 被引量:1
  • 5张倩,殷凯生,朱熠明,顾晓燕,马秀琴,王阿芳.内科微创肺减容术治疗兔肺气肿的实验研究[J].中华结核和呼吸杂志,2006,29(2):126-127. 被引量:7
  • 6Yim AP, Hwong TT, Lee TW, et al. Early results of endoscopic lung volume reduction for emphysema. J Thorac Cardiovasc Surg, 2004, 127 (6): 1564. 被引量:1
  • 7Fessler HE. Collateral ventilation, the bane of bronchoscopic volume reduction. Am J Respir Crit Care Med, 2005,171(5):423. 被引量:1
  • 8沈宁,姚婉贞,郝振婷,韩翔,马铁民,赵鸣武.经支气管镜肺减容术初探[J].中国呼吸与危重监护杂志,2006,5(1):31-34. 被引量:18
  • 9Toma TP, Hopkinson NS, Hillier J, et al. Bronchoscopic volume reduction with valve implants in patients with severe emphysema. Lancet, 2003, 361(9361):931. 被引量:1
  • 10Brenner M, Gonzalez X, Jones B, et al. Effects of a novel implantable elastomer device for lung volume reduction surgery in a rabbit model of elastase-induced emphysenxa. Chest, 2002, 121 (1) : 201. 被引量:1

二级参考文献13

  • 1Bellemare F,Cordeau MP,Couture J,et al.Effects of emphysema and lung volume reduction surgery on transdiaphragmatic pressure and diaphragm length.Chest,2002,121:1898-1910. 被引量:1
  • 2Ingenito EP,Reilly JJ,Mentzer SJ,et al.Bronchoscopic volume reduction:a safe and effective alternative to surgical therapy for emphysema.Am J Respir Crit Care Med,2001,164:295-301. 被引量:1
  • 3Toma TP, Hopkinson NS, Hillier J, et al. Bronchoscopic volume reduction with valve implants in patients with severe emphysema. lancet, 2003 , 361 : 931 - 933. 被引量:1
  • 4Cooper JD, Patterson GA, Sundaresan RS, et al. Results of 150 consecutive bilateral lung volume reduction procedures in patients with severe emphysema. J Thorae Cardiovasc Surg, 1996,112:1319- 1329. 被引量:1
  • 5Benditt JO, Lewis S, Wood DE, et al. Lung volume reduction surgery improves maximal O2 consumption, maximal minute ventilation, 02 pulse, and dead space to tidal volume ratio during leg ergometry. Am J Respir Crit Care Med, 1997, 156:561 - 566. 被引量:1
  • 6Moy ML, Ingenito EP, Mentzer SJ, et al. Health-related quality of life improves following pulmonary rehabilitation and lung volume reduction surgery. Chest, 1999 , 115:383-389. 被引量:1
  • 7Criner G J, Cordova FC, Fumkawa S, et al. Prospective randomized trial comparing bilateral lung volume reduction surgery to pulmonary rehabilitation in severe chronic obstructive pulmonary disease. Am J Respir Crit Care Med, 1999, 160:2018- 2027. 被引量:1
  • 8Geddes D, Davies M, Koyama H, et al. Effects of lung volume reduction surgery in patients with severe emphysema. N Engl J Med, 2000, 343 : 239 - 245. 被引量:1
  • 9National Emphysema Treatment Trial Research Group. Patients at high risk of death after lung volume reduction surgery. N Engl J Med,2001 ,345:1075 - 1083. 被引量:1
  • 10Woolcock A J, Macklem PT. Mechanical factor influencing collateral ventilation in human, dog and pig lungs. J Appl Physiol,1971 ,30:99 -115. 被引量:1

共引文献20

同被引文献32

引证文献7

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部