摘要
2004年12月30日,广州城建开发伟城实业有限公司城总大楼发生重大火灾事故,过火面积约2500m2,直接财产损失80万元左右,无人员伤亡。在已知火灾事故原因和火灾蔓延的情况下,通过FDS程序,对起火部位房间内的火灾蔓延情况进行数值模拟,验证此次重大火灾事故的原因。
A disastrous fire broke out in Guangzhou urban construction development Weicheng industry Co. Ltd. in 30 December 2004. The burned area is about 2 500 m^2, the economic loss caused by fire is about 800 000 RMB,there was no one injured. On the condition of knowing the fire cause and fire spread, the fire spread in the room which fire originated was simulated by FDS, the fire cause was verified.
出处
《消防科学与技术》
CAS
2008年第8期617-620,共4页
Fire Science and Technology
关键词
火灾调查
数值模拟
原因认定
fire investigation
numerical simulation