期刊文献+

异步电动机定子绕组匝间短路故障检测新方法 被引量:26

A Novel Detection Method of Stator Winding Inter-turn Short Circuit Fault in Induction Motors
下载PDF
导出
摘要 定子绕组匝间短路是异步电动机常见故障之一,因此研究其检测方法具有重要意义。针对异步电动机定子绕组匝间短路与转子断条故障瞬态进行仿真并分析仿真结果,指出异步电动机转子故障对定子绕组匝间短路故障检测存在不利影响,甚至导致故障误判。提出计及转子故障时的异步电动机定子绕组匝间短路故障检测新方法,该方法关键在于预先采用频谱校正与自适应滤波技术滤除定子电流中由转子故障所导致的特征频率分量。大量仿真与实验结果表明,该方法可以避免将转子故障误判为定子绕组匝间短路故障,使定子绕组匝间短路故障识别可靠性大幅提高。 It is of great significance to investigate and improve the detection method of stator winding inter-turn short circuit fault in induction motors. The transient simulation of stator winding inter-turn short circuit fault, as well as broken rotor bar fault, has been completed. By thoroughly analyzing the simulation results, this paper points out that the detection methods of stator winding inter-turn short circuit fault, presented in the previous literature, may misinterpret broken rotor bar fault as stator winding inter-turn short circuit fault. And then, a novel detection method of stator winding inter-turn short circuit fault, which blends perfectly the spectrum correction and self-adaptive filter techniques, is proposed. Simulation and experimental results demonstrate that the novel method is immune to broken rotor bar fault and thus more reliable than those presented previously.
出处 《中国电机工程学报》 EI CSCD 北大核心 2008年第21期73-79,共7页 Proceedings of the CSEE
基金 国家自然科学基金项目(50407016)~~
关键词 异步电动机 定子绕组匝间短路 转子断条 频谱校正 白适应滤波 故障检测 induction motor stator winding inter-turn short circuit broken rotor bar spectrum correction selfadaptive filter detection method
  • 相关文献

参考文献18

  • 1IAS Motor Reliability Working Group. Report of large motor reliability survey of industrial and commercial installations, part Ⅰ-Ⅱ [J]. IEEE Transactions on Industry Applications, 1985, 21(4): 853-872. 被引量:1
  • 2IAS Motor Reliability Working Group. Report of large motor reliability survey of industrial and commercial installations, part Ⅲ [J]. IEEE Transactions on Industry Applications, 1987, 23(1): 153-158. 被引量:1
  • 3Olav V T, Magnus D. A survey of faults on induction motors in offshore oil industry, petrochemical industry, gas terminals, and oil refineries[J]. IEEE Transactions on Industry Applications, 1995, 31(5): 1186-1196. 被引量:1
  • 4Sottile J, Kohler J L. An on-line method to detect incipient failure of turn insulation in random-wound motors[J]. IEEE Trahsactions on Energy Conversion, 1993, 8(4): 762-768. 被引量:1
  • 5Andreas S, Howard G S, James P. Current monitoring for detecting inter-turn short circuits in induction motors[J]. IEEE Transactions on Energy Conversion, 2001, 16(1): 32-37. 被引量:1
  • 6Kliman G B, Premerlani W J, Koegl R A, et al. Sensitive on-line turn-to-turn fault detection in AC motors[J]. Electric Machines and Power Systems, 2000, (28): 915-927. 被引量:1
  • 7许伯强,李和明,孙丽玲,王永宁.异步电动机定子绕组匝间短路故障检测方法研究[J].中国电机工程学报,2004,24(7):177-182. 被引量:53
  • 8Sergio M A, Cruz A J, Marques C. Multiple reference frames theory: a new method for the diagnosis of stator faults in three-phase induction motors[J]. IEEE Transactions on Energy Conversion, 2005, 20(3): 611-619. 被引量:1
  • 9Behrooz M, Richard J P, Nabeel A O D. Interturn fault diagnosis in induction motors using the pendulous oscillation phenomenon [J]. IEEE Transactions on Energy Conversion, 2006, 21(4): 871-882. 被引量:1
  • 10孙丽玲,李和明,许伯强.笼型异步电动机转子断条与定子绕组匝间短路双重故障研究[J].电工技术学报,2005,20(4):38-44. 被引量:11

二级参考文献50

共引文献314

同被引文献209

引证文献26

二级引证文献194

相关作者

内容加载中请稍等...