结合某展览中心热力站改造实例,介绍了具有不同用热性质的多种用户的旧热力站节能改造的思路,对旧热力站改造所应达到的功能要求、控制策略、实施步骤进行了详细描述,给出了热力站运行调节控制软件的编制依据。通过改造前后供热量和供热收费的比较可以看出节能改造的实际效果,给出了旧热力站节能改造的设计方法。
Taking the reformation of an exhibition centre substation as an example, presents the thoughts of energy efficient reformation for the former substation with multiplex customers and multiform heating demands. Describes in detail the function demands, control strategies and implement processes of substation reformation and gives the compiling principle of operating regulation and control software for the substation. The effect of energy efficient reformation is proved by comparing the heating supply and heating charge between the former substation and the rebuilt one. Presents some design methods for energy efficient reformation of existed substations.
出处
《暖通空调》
北大核心
2008年第5期93-96,共4页
Heating Ventilating & Air Conditioning
关键词
热力站
供热系统
节能改造
控制策略
substation, heating system, energy efficient reformation, control strategy