摘要 为确定火炸药粉尘环境用防爆电气设备的型式参数,设计了壳体粉尘侵入量试验,分别测试了止口接合面不同间隙和不同止口高度下的进粉量,进行了结果分析。试验结果表明:控制接合面间隙在0.10mm以下,止口高度在9mm以上时,能起到较好的防尘效果。 In order to determine the model of electrical apparatus used in environment with propellant and explosive dust, the test for measuring the amount of invaded dust were carried out. The effects of the gap of joint surface and the height of rabbet on the amount of invaded dust were investigated. The results showed that it would have good performance of dust control if the gap of joint surface was lower than 0.10mm and the height of rabbet was over 9mm.
出处 《火工品》 CAS CSCD 北大核心 2008年第2期38-40,共3页 Initiators & Pyrotechnics
关键词 火炸药粉尘 电气设备 接合面间隙 止口高度 Explosive dust Electrical equipment Gap of joint surface Height of rabbet
  • 相关文献

参考文献5

  • 1IEC 60034-5:2004 Rotating electrical machines Part 5:Degrees of protection provided by the integral design of rotating electrical machines(IP code)-Classificafion, IDT[S]. IEC,2000. 被引量:1
  • 2ZHU Fang,WANG Peilan. Safety analysis of explosion -proof electrical apparatus used in hazardous location present powder and explosives[C]//Theory and Practice of Energetic Materials. Beijing:Science Press,2006:1113-1 118. 被引量:1
  • 3王保民,肖林,安琴.TNT 粉尘爆炸压力发展过程研究[J].华北工学院学报,1997,18(3):223-227. 被引量:5
  • 4IEC 61241-0-2004 Electrical apparatus for use in the presence of combustible dust -- -- Part 0:General requirements[S].IEC,2004. 被引量:1
  • 5王军.火炸药危险场所爆炸参数研究分析[J].电气防爆,2004(1):1-12. 被引量:7