期刊文献+

风电机组等效模型对机组暂态稳定分析结果的影响 被引量:60

Effect of Equivalent Models of Wind Turbines on Analysis Results of Transient Stability for Wind Generator Systems
下载PDF
导出
摘要 该文应用等效集中质量法,建立了同时考虑风力机叶片弯曲柔性以及风力机和发电机之间传动轴扭转柔性的风力机3个质量块等效模型。结合并网笼型异步发电机的电磁暂态模型,以额定功率330kW(MADE-AE30)和3MW的风力发电机组为例,在电网电压骤降和机械大扰动下,与风力机传统1个、2个质量块等效模型的机组暂态稳定性进行了仿真比较。分析了叶片不同弯曲柔性、不同折断点位置对3MW风电机组电暂态稳定性的影响。结果表明,该文建立的风力机等效模型对准确分析风力发电机组暂态稳定性是必要和有效的。 By using equivalent lump mass method, a three-mass wind turbine equivalent model is presented considering both the bending flexibility of blades and the torsional flexibility of the drive-train shaft between the wind turbine and induction generator. Combined with the electrical transient models of a grid-connected squirrel cage induction generator (SCIG), during a grid voltage drop and a mechanical large disturbance, the transient stability of two wind generator systems with rated power 330 kW (MADE-AE30) and 3 MW are investigated, respectively. Simulation results are also compared with those of the typical single-mass and two-mass equivalent models of wind turbines. The effects of the different bending flexibility of blades and the different position of blades breakpoint on the electrical transient stability of the rated power 3 MW wind turbine are also analyzed. The results show that the proposed equivalent model of wind turbine is essential and valid to analyze accurately the transient stability of wind turbine systems.
出处 《中国电机工程学报》 EI CSCD 北大核心 2008年第17期105-111,共7页 Proceedings of the CSEE
基金 国家自然科学基金项目(50607022)~~
关键词 风力发电 暂态稳定性 笼型异步发电机 风力机 叶片柔性 传动轴 等效模型 wind power generation transient stability squirrel cage induction generator wind turbine blade flexibility drive-train shaft equivalent models
  • 相关文献

参考文献20

  • 1Clemens Jauch Julijia Matevosyan, Thomas Ackermann Sigaid Bolik. International comparison of requirements for connection of wind turbines to power systems[J]. Wind Energy, 2005, 8(3): 295-306. 被引量:1
  • 2Chen Z. Issues of connecting wind farms into power systems[C]. 2005 IEEE/PES Transmission and Distribution Conference& Exhibition: Asia andPacific, Dalian, China, 2005. 被引量:1
  • 3杨秀媛,肖洋,陈树勇.风电场风速和发电功率预测研究[J].中国电机工程学报,2005,25(11):1-5. 被引量:583
  • 4陈树勇,戴慧珠,白晓民,周孝信.风电场的发电可靠性模型及其应用[J].中国电机工程学报,2000,20(3):26-29. 被引量:233
  • 5Ledesma P, Usaola J, Rodriguez J L. Transient stability of a fixed speed wind farm[J]. Renewable Energy, 2003, 28(9): 1341-1355. 被引量:1
  • 6Sun Tao, Chen Z, Blaabjerg F. Transient stability of DFIG wind turbines at an external short-circuit fault [J]. Wind Energy, 2005, 8(3): 345-360. 被引量:1
  • 7Holdsworth L, Wu X G, Ekanayake J B, et al. Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances[J]. IEE Proc. Generation, Transmission and Distribution, 2003, 150(3): 343-352. 被引量:1
  • 8Akhmatov V, Nielsen A H. Fixed-speed aclive-stall wind turbines in offshore applications[J]. European Trans. on Electrical Power, 2005, 15(2): 1-112. 被引量:1
  • 9Trudnowsld D J, Khan J M, Petritz E M. Fixed-speed wind generator and wind park modeling for transient stability studies[J]. IEEE Transactions on Power Systems, 2004, 19(4): 1911-1917. 被引量:1
  • 10李晶,宋家骅,王伟胜.大型变速恒频风力发电机组建模与仿真[J].中国电机工程学报,2004,24(6):100-105. 被引量:274