摘要 目的探讨及评价螺旋CT在骨盆骨折的诊断及治疗中的临床价值。方法对拥有完整的X线、CT及螺旋CT影像资料的34例骨盆骨折患者进行回顾性分析,并在三种影像检查方法间进行比较。结果三种方法间诊断率有显著性差异(P<0.01),二维CT与三维重建间差异无显著性(P>0.05)。结论CT三维重建清晰立体,可以根据需要从不同的方位显示骨盆骨折损伤情况,指导临床诊断及手术意义重大。 Objective To investigate and evaluate the clinical value of three - dimensional CT in diagnosis and treatment of pelvic fracture. Methods A retrospective analysis including 34 cases of pelvic fractures with X - rays, CT and three - dimensional CT films hve been finished, The radiological characteristics andresuhs were compared with three kinds of radioactive examination. Results The positive rate of CT scan and CT theree - dimensional reconstruction were relativelyhigher than X - ray( P 〈 0. 01 ), there were no significant difference between CT scan and CT three - dimensional( P 〉 0.05 ). Conclusion With clear stereo, CT three - dimensionaL reconstruction can show the injury in different directions, which was of clinical significance in diagnosis and operation.
出处 《临床和实验医学杂志》 2008年第5期19-20,共2页 Journal of Clinical and Experimental Medicine
关键词 CT 三维重建 骨盆骨折 临床治疗 Three - dimensional CT Pelvic fracture
  • 相关文献

参考文献8

二级参考文献31

  • 1[1]Klingenbeck - Regn K, Schaller S, Flohr T, et al. Subsecond multi slice computed tomography: basics and applications. Eue J Radiol, 1999,31:110- 124 被引量:1
  • 2[2]Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: scanning techniques and clinical applications. Radiographics, 2000, 20:1787 - 1806 被引量:1
  • 3[3]Rubin GD, Shiau MC, Schmidt A J, et al. Computed tomographic an giography: histotical perspective and new state - of- the - art using multi detector - row helical computed tomography. J Comput Assist Tomogr, 1999,23(suppll): 83 - 90 被引量:1
  • 4[4]Taguchi K, Aradate H. Algorithm for image reconstruction in multi slice CT. Med Phy, 1998,25: 550 - 561 被引量:1
  • 5[5]Hu H. Multi - slice helical CT: scan and reconstruction. Med Phy, 1999,26:5- 18 被引量:1
  • 6[6]MeCollough CH, Zink FE. Performance evaluation of a multi - slice CT system. Med Phy, 1999,26( 11 ) :2223 - 2230 被引量:1
  • 7[7]Caldemeyer KS, Sandrasegaran K, Shinaver CN, et al. Temporal bone: comparison of isotropic helical CT and conventioal direct axial and coronal CT. AJR, 1999,172:1675 - 1682 被引量:1
  • 8[8]Horton KM, Fishman EK. Multi - detector row CT of mesenteric ischemia: can it be done? Radiographics,2001,21:1463- 1473 被引量:1
  • 9[9]lawler LP, Fishman EK. Multi - detector row CT of thoraci disease with emphasis on 3D volume rendering and CT andiography. Radiographics, 2001,21:1257 - 1273 被引量:1
  • 10[10]Broderick LS, Shemesh J, Wilensky RL, et al. Measurement of coro nary artery calcium with dual - slice helical CT compared with coronary angiography: evaluation of CT scoring methods, interob server variations, and reproducibility. A JR, 1996, 167:439 - 444 被引量:1

共引文献74

同被引文献51

引证文献10

二级引证文献54

相关作者