摘要
介绍了无锡市城北污水处理厂采用的升流式污泥床水解池的设计参数,结合实际工程运行情况,对其在城市综合污水处理中的应用进行了研究探讨。结果表明,该工艺对COD、BOD5、SS有良好的去除效果,总出水水质达到国家一级B排放标准,对同类型城市综合污水处理厂污水的治理有一定借鉴意义。
The design parameters of up-flow sludge bed hydrolytic tank in Wuxi Cheng-bei waste water plant were introduced, And the operating condition of on-site project was combined with the technology of up-flow sludge bed hydrolytic tank to treat urban comprehensive sewage, The results showed that the removal rates of COD,BODs,and SS were very well, the effluent quality meets the requirements in the national first B discharge standards, This experiment provided a reference to the wastewater treatment of other similar urban comprehensive sewage.
出处
《水处理技术》
CAS
CSCD
北大核心
2008年第5期84-87,共4页
Technology of Water Treatment
关键词
升流式污泥床水解池
污水处理厂
工程设计
up-flow sludge bad hydrolytic tank
waste water plant
project designing