期刊文献+

化学发光法测定氨磷汀研究 被引量:2

Chemiluminescence Determination of Amifostine
下载PDF
导出
摘要 实验发现,铈(Ⅳ)可以氧化氨磷汀产生弱的发光,而罗丹明6G(Rh6G)能大大增强此发光,由此建立了一种化学发光法测定氨磷汀的新方法。该方法的线性范围为1.0×10^-7~1.0×10^-5mol/L,检出限为6.4×10^-8mol/L。对1.0×10^-6mol/L的氨磷汀进行11次平行测定的相对标准偏差为2.6%。该法用于氨磷汀注射液中氨磷汀含量的测定,获得满意结果。 Based on the chemiluminescence reaction of amifostine and Ce(Ⅳ ) in sulfuric acid medium significantly sensitized by rhodamine 6G, a novel chemiluminescence method for the determination of amifostine was established. The linear relationship between the intensity of chemiluminescence and the concentration of amifostine is in the range of 1.0×10^-7 ~1. 0 ×10^-5 mol/L. The detection limit is 6.4×10^-8 mol/L and the relative standard deviation is 2. 6% for 11 measurements of 1. 0 ×10^-6 mol/L standard solution. This method has been successfully applied to the determination of amifostine in amifostine for injection with a recovery range of 98.0%-104.0%. The method is simple, convenient and sensitive.
出处 《分析科学学报》 CAS CSCD 2008年第2期149-152,共4页 Journal of Analytical Science
基金 华中科技大学理科基金(No.0101013008) 人才引进基金(No.0101013148)
关键词 氨磷汀 化学发光 罗丹明6G Amifostine Chemiluminescence Cerium Rhodamine 6G
  • 相关文献

参考文献13

  • 1Lawrence T S,Robertson J M,Anscher M S,Jirtle R L,Ensminger W D,Fajardo L F.Int.J.Radiat.Oncol.Biol.Phys.[J],1995,31(5):1237. 被引量:1
  • 2Culy C R,Spencer C M.Drugs[J],2001,61:641. 被引量:1
  • 3Swynnerton N F,McGovern E P,Nino J A,Mangold D J.Int.J.Radiat.Oncol.Biol.Phys.[J],1984,10:1521. 被引量:1
  • 4Fahey R C,Newton G L.Int.J.Radiat.Oncol.Biol.Phys.[J],1985,11:1193. 被引量:1
  • 5Utley J F,Seaver N,Newton G L,Fahey R C.Int.J.Radiat.Oncol.Biol.Phys.[J],1984,10:1525. 被引量:1
  • 6Swynnerton N F,Huelle B K,Mangold D J,Ludden T M.Int.J.Radiat.Oncol.Biol.Phys.[J],1986,12:1495. 被引量:1
  • 7Bai F,Kirstein M N,Hanna S K,Stewart C F.J.Chromatogr.B[J],2002,772(2):257. 被引量:1
  • 8Korst A E C,Vermorken J B,Vijgh W J F.J.Chromatogr.B[J],1997,693(1):167. 被引量:1
  • 9Warner D L,Burke T G.J.Chromatogr.B[J],1997,691(1):161. 被引量:1
  • 10Shaw L M,Bonnet H S,Turrisi A,Norfleet A L,Kligerman M M.J.Liq.Chromatogr.[J],1986,9:845. 被引量:1

同被引文献7

  • 1Kouvaris JR. Kouloulias VE, Vlahos LJ. Amifostine: TheFirst Selcctive-Target and Broad-Spectrum Radioprotector[J]. The2007,12(6) :738 - 747. 被引量:1
  • 2Bai F- Kirstein MN,Hanna SK, et al. New liquidchromatographic assay with electrochemical detection forthe measurement of amifostine and WR1065 [J]. JChromatogr B Analyt Technol Biomed Life Sci. 2002 ,772?2):257 - 265. 被引量:1
  • 3Bolner A, Barbato L, Tagliaro P', et al. Determination ofapomorphine in human plasma by ?ilumina extraction andhigh-performance liquid chromatography withelectrochemical detection [J]. Forejisic Sci Int,1997,89( 1-2):81 -01. 被引量:1
  • 4Kouvaris JR,Kouloulias VE,Vlahos LJ.Amifostine:the first selective-target and broad-spectrum radioprotector[J].Oncologist,2007,12(6):738. 被引量:1
  • 5Bai F,Kirstein MN,Hanna SK,et al.New liquid chro-matographic assay with electrochemical detection for the measurement of amifostine and WR1065[J].J Chro-matogr B Analyt Technol Biomed Life Sci,2002,772(2):257. 被引量:1
  • 6Bolner A,Barbato L,Tagliaro F,et al.Determination of apomorphine in human plasma by alumina extraction and high-performance liquid chromatography with electro-chemical detection[J].Forensic Sci Int,1997,89(1/2):81. 被引量:1
  • 7孙伟光,卢婷利,陈涛,于洋.高效液相色谱-荧光胺柱前衍生法测定氨磷汀微球中氨磷汀的含量[J].中国医院药学杂志,2009,29(14):1189-1192. 被引量:2

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;