摘要 逆流色谱是一种无固态支撑物的液液色谱 ,它的色谱动力学过程有其特殊性 ,分析逆流色谱的动力学过程 ,推导适用于逆流色谱的速率方程式 ,结合实验 ,讨论影响色谱峰展宽的因素 ;理论推导和实验的结果都显示 ,管径、容量因子。 Dynamics in countercurrent chromatography, a kind of liquid liquid chromatography without solid matrix, is very different to that in other liquid liquid chromatography. Dynamics in countercurrent chromatography was analyzed and the rate equation that fits countercurrent chromatography was derived out. Some experiments were done to measure H(plate height) of two kinds of CCPC(centrifuge countercurrent partition chromatography) columns. The results of both theoretical deriving and experiments reveal that the diameter of column, capacity factor, mass transfer coefficient, the average diameter and velocity of mobile phase droplets are main factors that determines H. Mathematics analysis is given.