期刊文献+

后张预应力高性能灌浆料的配制试验研究及性能分析 被引量:8

Property Analysis and Experimental Study of Proportion of Post-tensioned High-performance Grouts
下载PDF
导出
摘要 选取了能全面表征灌浆料质量的性能参数、有效的试验方法和合适的性能指标;选取了合适的灌浆料专用复合外加剂和水泥,经过试验对比,确定了搅拌方式、搅拌速度、搅拌时间等工艺参数;确定了高性能灌浆料的配合比;配制出了低水灰比、良好可泵性、高体积稳定性、零泌水、高抗氯离子渗透性等优良性能的后张预应力灌浆料;分析了搅拌工艺、水灰比和水泥品种对灌浆料各项性能的影响。 Performance parameters characterizing qualities of grouts, effective testing methods and proper performance indexes are selected; Technological parameters including mixing method, mixing speed and mixing time are selected according to experiments based on proper materials including cement and special composite admixture for grouts; The mixing ratio of high-performance grouts is given; High-performance grouts with low water-cement ratio, excellent pumpablity, high volume stability, zero bleeding, good permeability to resist chloride ion's penetration are developed; The influence of mixing technology, water-cement ratio and different kinds of cement to the grouts performance are analyzed.
作者 谷坤鹏
出处 《水运工程》 北大核心 2008年第3期21-26,共6页 Port & Waterway Engineering
关键词 后张预应力孔道高性能灌浆料 搅拌工艺 配合比 泌水 膨胀率 抗氯离子渗透性能 post-tensioned high-performance grouts mixing technology mix proportion bleeding expansion ratio permeability to resist chloride ion's penetration
  • 相关文献

参考文献10

  • 1FIg Committee on Grouting Specifications. Guide Specification for Grouting of Post-Tensioned Structures [R] . America: Post-Tensioning Institute, 2003. 被引量:1
  • 2Florida Department of Transportation. FDOT Standard Specifications [ R] . America: Florida Department of Transportation, 2002. 被引量:1
  • 3Hope BB Ip AK. Grout for Post-Tensioning Ducts [J] . ACI Materials Journal, 1988, 120 (4) : 234-240. 被引量:1
  • 4Schokker A J, Koester BD, Breen JE, et al Development of High Performance Grouts for Bonded Post-Tensioned Structures[R] . Research Rep., 1999. 被引量:1
  • 5Grouting specifications committee Post Tensioning Grouts Specifications [R] , America: Groutingspecificationscommittee,2002. 被引量:1
  • 6ASTM C939-97, Standard Test Method for Flow of Grouts for Preplaced-Aggregate Concrete (Flow Cone Method) [S]. 被引量:1
  • 7ASTM C940-98a, Standard Test Method for Expansion and Bleeding of Freshly Mixed Grouts for Preplaced-Aggregate Concrete in the Laboratory [S] . 被引量:1
  • 8ASTM C1090-96, Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from Hydraulic-Cement Grouts [S] . 被引量:1
  • 9ASTM C1202-97, Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion penetration [S] . 被引量:1
  • 10ASTM C942-99, Standard Test Method for Compressive Strength of Grouts For Preplaced-Aggregate Conerete in the Laboratory[S] . 被引量:1