期刊文献+

热像系统温度特性分析研究

Research and Analysis about Temperature Characteristics for Thermal Imaging System
下载PDF
导出
摘要 军用非致冷红外热像仪要求有很好的环境温度的适应性,其工作温度要求一般为-40-60℃。根据国内常见的非晶硅型非致冷焦平面器件的材料特性、结构原理及焦平面的热平衡方程,研究了焦平面衬底稳定工作温度与噪声等效温差的关系,并在MATLAB软件中模拟了其关系曲线,为此种类型的焦平面在低温下操作时提高图像质量和降低功耗,提出了新的解决方案。 Military uncooled thermal imager must be high adaptable to extreme environment,and the range of operation temperature is -40 - 60 ℃. Based on the material features,structure and equation of thermal equilibrium of a-Si uncooled focal plane arrays, the relation between inner temperature and NETD was researched. The relation curves were simulated in MATLAB. At last, the new resolution design is presented to assure the image quality and decrease power dissipation.
出处 《半导体光电》 EI CAS CSCD 北大核心 2008年第1期123-125,共3页 Semiconductor Optoelectronics
关键词 红外与夜视技术 非致冷焦平面 A-SI 噪声等效温差 功耗 infrared and night vision uncooled FPA a-Si NETD power dissipation
  • 相关文献

参考文献4

二级参考文献20

  • 1Lenggenhager R,Baltes B,Peer J, et al. Thermoelectric infrared sensors by CMOS technology [J]. IEEE Electron Device Lett. , 1992,13 (9) :454-456. 被引量:1
  • 2Noda M,Mukaigawa T, Hashimoto K, et al. A simple detector pixel of dielectric bolometer mode and its device structure for uncooled IR image sensor [J].Proc. SPIE, 1999,3 698:565-573. 被引量:1
  • 3Dobrzanski L, Nossarzewska-Orlowska E, Nowak Z, et al. Micromachined silicon bolometers as detectors of soft X-ray, ultraviolet, visible and infrared radiation[J]. Sensors and Actuators A, 1994,60:154-159. 被引量:1
  • 4Vedel C, Martin J, Ouvrier Buffet J, et al. Amorphous silicon based uncooled microbolometer IRFPA[J].Proc. SPIE, 1999,3 698 : 276-283. 被引量:1
  • 5Torres A,Kosarev A,Garcia Cruz M L,et al. Uncooled micro-bolometer based on amorphous germanium film[J]. J. Non-Crystalline Solids, 2003,329 (1-3) : 179-183. 被引量:1
  • 6Sedky S,Fiorini P,Baert K,et al. Characterization and optimization of infrared poly-SiGe holometers[J]. IEEE Trans. Electron Devices, 1999,46(4):675-682. 被引量:1
  • 7MacDonald M E. Niobium microbolometers for farinfrared detection[J]. IEEE Trans. Microwave Theory and Technique, 1995,43(4) : 893-896. 被引量:1
  • 8Wada H, Sone T, Hata H, et, al. YBaCuO uncooled microbolometer IR FPA[J]. Proc. SPIE, 2001,4 369:297-304. 被引量:1
  • 9Wood R A. High performance infrared imaging with monolithic silicon focal planes operating at room temperature[A]. IEDM' 1993[C].1993 :175-177. 被引量:1
  • 10Wada H N M,Kanzaki M. Fabrication process for 256×256 bolometer-type uncooled infrared dectector[J].Proc. SPIE, 1997,3 224:40-51. 被引量:1