期刊文献+

基于大景深三维扫描系统对RAC标定法的修正 被引量:3

Modification of RAC Camera Calibration Method Based on Large Depth-of-view 3D Laser Scanner
下载PDF
导出
摘要 基于大景深三维扫描系统的倾斜摄像机模型,推导了新的物像关系并修正了Tsai的RAC标定法.利用修正后的RAC标定法对大景深扫描系统的摄像机进行了标定,实验结果表明修正后的RAC标定法适用于倾斜的摄像机系统,标定准确度可以达到0.03mm. Base on the tilted camera model, new obiect-image equations are derived theoretically and the RAC method of Tsai is modified. Using the modified RAC method, the camera of large depth-of-view 3D laser scanning system is calibrated successfully. The experimental results show that the modified RAC method can solve the titled camera model. The standard deviation of calibration is lower than 0.03 ram.
出处 《光子学报》 EI CAS CSCD 北大核心 2008年第2期405-409,共5页 Acta Photonica Sinica
关键词 计算机视觉 摄像机标定 RAC标定法 景深 三维扫描系统 Computer vision Camera calibration RAC method Depth-of-view 3-D scanning system
  • 相关文献

参考文献10

二级参考文献19

  • 1Li Bing, Luo Yiping, Sui Liansheng, et al. Accuracy analysis for multi light-knife laser scanning system.Proceedings d 2nd International Symposium on Instrumentation Science and Technology,Harbin:Harbin Institute of Technology Press, 2002,2:381 -2-385. 被引量:1
  • 2Jin Guanchang,Opt Eng,1989年,28卷,11期,1211页 被引量:1
  • 3Srinivasan V,Appl Opt,1984年,23卷,18期,3105页 被引量:1
  • 4Longuet-Higgins H C. A computer algorithm for reconstructing a scene from two projections. Nature,1981,293(10): 133~135. 被引量:1
  • 5Ma S D. A Self-calibration technique for active vision system. IEEE Trans Robotics and Automation, 1996,12(1): 114~120. 被引量:1
  • 6Caprile B, Torre V. Using vanishing points for camera calibration. Int'1. J Computer Vision, 1990,4 (2): 127 ~140. 被引量:1
  • 7Cipolla R, Drummond T W, Robertson D. Camera Calibration from Vanishing Points in Images of Architectural Scenes. Proc. British Machine Vision Conf. , T. Pridmore and D. Elliman, eds. ,Nottingham, UK. 1999. 382~391. 被引量:1
  • 8Wong K Y K, Mendonca P R S, Cipolla R. Camera calibration from surfaces of revolution. PAMI, 2003,25(2) :147~161. 被引量:1
  • 9Kogecka J, Zhang W. Efficient Computation of Vanishing Points. Proceedings of the 2002 IEEE International Conference on Robotics and Automation, ICRA‘ 02,Washington DC. 2002. 223~228. 被引量:1
  • 10Guo Q W, Zhen Y H, Ma S D. Camera Calibration by Vanishing Point And Cross Ratio. Acoustics, Speech,and Signal Processing, ICASSP-89. , International Conference on, Glasgow UK. 1989. 1630~1633. 被引量:1

共引文献59

同被引文献16

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...