摘要 将鲁米诺(luminol)和高锰酸根同时固定在阴离子交换树脂柱中,磷酸盐缓冲溶液既作为洗脱剂洗脱树脂中的离子,又作为碱性介质,引起KMnO4氧化Luminol产生化学发光,在铅的作用下在样品池中产生后续化学发光,建立了一种测定铅的流通式化学发光传感器。传感器的线性响应范围为5.0×10^-8~1.0×10^-5 g/mL,检出限为3×10^-8 g/mL(3σ)。整个分析过程可以在1min内完成。对2.0×10^-6 g/mL的样品进行9次平行测定,其相对标准偏差为3.2%。传感器在200h内可以重复使用300次。应用于汽油中铅(Ⅱ)的测定结果令人满意。 Chemiluminescence(CL) reagent luminol and permanganate were electrostatically immobilized on anion exchange resin separately, and a continuous flow sensor for the determination of lead ions combined with controlled-reagent-release technology in a FIA-CL-system was constructed. Lead ions were sensed by their enhancing effect on the follow-up CL reaction of luminol-KMnO4, which were eluted from the anion exchange column. The calibration curve was linear in the range of 5.0×10^-8 - 1.0×10^-5 g/mL, and the detection limit was 3×10^-8 g/mL for lead(3σ). A complete analysis could be performed wthin 1 min with a relative standard deviation of 3.2% (2. 0×10^-6 g/mL, n =9). The sensor showed remarkable stability and could be easily reused over 300 times during 200 h. The sensor has successfully been applied to the determination of lead in gasoline samples.