期刊文献+

长春地区竖直埋管式地下换热井温度变化研究 被引量:2

Temperature changes in underground heat exchange wells with vertical closed-loop pipes in Changchun area
下载PDF
导出
摘要 针对竖直地埋管地源热泵系统运行特点,开发了地下换热井的测温系统。测量了地源热泵系统运行前换热井内的初始温度,推导出了适合长春地区的初始地温拟合方程。测量了地源热泵系统冬季供暖运行工况下地下换热井内的温度变化数据,总结出该地区冬季供暖时换热井内温度的变化规律。 In view of the operational characteristics of ground-source heat pump systems with vertical ground heat exchangers, develops an underground temperature measuring system. Measures the initial temperature in underground heat exchange wells before heat pump system operating, and obtains a fitted equation of initial underground temperature for Changchun area. Measures the temperature in wells during heat pump system operating in winter heating mode, and summarizes the change patterns of the temperature in wells in heating mode in this area.
机构地区 吉林大学
出处 《暖通空调》 北大核心 2008年第1期11-13,76,共4页 Heating Ventilating & Air Conditioning
基金 中国地质调查局<国土资源大调查>项目--浅层地热能钻采新技术研究与示范工程课题(编号:200220170012) 吉林大学985工程二期--东北资源与环境科技创新平台吉林大学大学生科技创新基金(编号:2004CX02)
关键词 竖直埋管 地源热泵 换热井 温度 vertical closed-loop pipe, ground-source heat pump, heat exchanger well, temperature