小主动脉瓣环患者生物瓣与机械瓣置换术后心功能变化的比较 被引量:11

Comparing Study of Heart Function of Biological Valves Replacement with Mechanical Valves Replacement in Patients with Small Aortic Root
下载PDF
导出
摘要 目的分析比较小主动脉瓣环(直径≤21mm)患者人工生物瓣置换与人工机械瓣置换术后心功能的变化,探讨人工生物瓣置换术后是否存在植入瓣膜与患者不匹配(PPM)现象。方法40例主动脉瓣环直径≤21mm的患者,其中20例置换人工生物瓣(生物瓣组),20例置换人工机械瓣(机械瓣组)。采用彩色多普勒超声心动图于术前和术后6个月~1年期间,检测两组患者的左心室射血分数(LVEF)、左心室短轴缩短率(LVFS)、左心室重量指数、瓣膜有效开口面积/体表面积的比值(EOAI)和主动脉瓣跨瓣压差的变化,并进行对比分析。结果术后6个月~1年,两组患者LVEF、LVFS和EOAI均较术前明显升高,左心室重量指数和主动脉瓣跨瓣压差均较术前明显减小或降低。所有患者术后EOAI为0.88~1.32cm2/m2,术后6个月~1年生物瓣组与机械瓣组比较:LVEF79%±8%vs.81%±10%;LVFS43%±9%vs.37%±8%;EOAI1.11±0.14vs.0.92±0.11;左心室重量指数89.10±16.70g/m2vs.95.30±15.10g/m2;主动脉瓣跨瓣压差18.80±12.60mmHgvs.22.30±12.00mmHg,差异无统计学意义(P>0.05)。结论小主动脉瓣环患者(直径≤21mm)置换人工生物瓣术后左心功能指标明显改善,无PPM现象。 Objective To compare the change of left heart function in patients with biological valves replacement of small aortic root with mechanical valve replacement, and to find whether there is prosthesis-patient mismatch (PPM) or not after operation. Methods Left ventricular ejection fraction (LVEF), left ventricular fractional shortening (LVFS), left ventricular mass index, the indexed effective orifice area (EOAI), and peak pressure gradients across aortic valve in 20 patients with small aortic root(≤21mm in diameter) receiving biological valves replacement (biological valves group) were studied by Doppler echocardiography before the operation and 6 months to 1 year after operation. The results were compared with those of 20 patients who received mechanical valves replacement (mechanical valves group). Results Comparing with those before operation, there was a significant increase in LVEF, LVFS, EOAI of all patients 6 months to 1 year after operation . There was a significant reduction in the left ventricular mass index,peak pressure gradients across aortic valve in all patients. EOAI of all patients were between 0. 88 cm^2/m^2 and 1. 32 cm^2/m^2. LVEF, LVFS, EOAI, left ventricular mass index, and peak pressure gradients across aortic valve between biological valves group and mechanical valves group (79% ± 8% vs. 81% ± 10%; 43%±9% vs. 37%±8%; 1.11±0.14 vs. 0.925=0.11; 89.10±16.70g/m^2vs. 95.30±15.10 g/m^2; 18.80± 12. 60 mmHg vs. 22.30±12.00 mmHg) showed no significant difference 6 months to 1 year after operation (P〉 0. 05). Conclusion Patients with small aortic root receiving biological valves have a significant increase in the left heart function,and have no PPM.
出处 《中国胸心血管外科临床杂志》 CAS 2008年第1期7-9,共3页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
关键词 小主动脉瓣环 人工生物瓣 左心功能 植入瓣膜与患者不匹配 Small aortic root Biological valve Left ventricular function Prosthesis-patient mismatch
  • 相关文献

参考文献12

  • 1Borger MA, Prasongsukarn K, Armstrong S, et al. Stentless aortic valve reoperations: a surgical challenge. Ann Thorac Surg, 2007,84(3) : 737-743. 被引量:1
  • 2Westaby S, Horton M, Jin XY, et al. Survival advantage of stentless aortic bioprostheses. Ann Thorac Surg, 2000,70 (3) : 785-791. 被引量:1
  • 3David TE, Pollick C, Bos J. Aortic valve replacement with stemless porcine aortic bioprosthesis. J Thorac Cardiovasc Surg, 1990, 99(1):113-118. 被引量:1
  • 4Cartier PC, Dumesnil JG, Metras J, et al. Clinical and hemodynamic performance of the Freestyle aortic root bioprosthesis. Ann Thorae Surg, 1999,67(2) 5345-349. 被引量:1
  • 5Kunihara T, Schmidt K, Glombitza P,et al. Root replacement using stentless valves in the small aortic root : a propensity score analysis. Ann Thorac Surg, 2006,82(4) : 1379-1384. 被引量:1
  • 6Rahimtoola SH. The problem of valve prosthesis-patient mismatch. Circulation, 1978,58(1):20-24. 被引量:1
  • 7Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact and prevention. Heart, 2006, 92 (8): 1022-1029. 被引量:1
  • 8Pibarot P, Dumesnil JG. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention. J Am Coll Cardiol,2000, 36(4) : 1131-1141. 被引量:1
  • 9De Carlo M, Milano AD, Nardi C, et al. Serial Doppler echocardiographic evaluation of small-sized sorin bicarbon prostheses. J Thorac Cardiovasc Surg, 2003,126(2) : 337-343. 被引量:1
  • 10王红兵,周更须,郑奇军,陈文生,蔡振杰,刘维永.小主动脉瓣环患者主动脉瓣置换术41例[J].中国胸心血管外科临床杂志,2006,13(1):52-53. 被引量:8

二级参考文献18

  • 1Bortolotti U, Scioti G, Milano A, et al, Enlargement of the aortic annulus with glutaraldehyde fixed bovine pericardium during aortic valve replacement. J Heart Valve Dis, 1998,7 (3) :299-304. 被引量:1
  • 2Ghosh P, Kumar S, Pandey S, et al. Small aortic annulus: a functional definition. Ann Thorac Cardiovasc Surg, 1998,4 (5):251-261. 被引量:1
  • 3Kitamura M, Satoh M, Hachida M, et al. Aortic valve replacement in small aortic annulus with or without annular enlargement. J Heart Valve Dis, 1996,5(Suppl 3):S289-S293. 被引量:1
  • 4Hanayama N, Christakis GT, Mallidi HR, et al. Patient prosthesis mismatch is rare after aortic valve replacement: valve size may be irrelevant. Ann Thorac Surg, 2002, 73(6): 1822-1829. 被引量:1
  • 5Bartels C, Sievers HH. Successful dilatation of the small aortic root for implantation of a larger valve prosthesis. J Heart Valve Dis, 1999,8(5): 507-508. 被引量:1
  • 6Molina JE. Enlargement of the aortic annulus using a double-patch technique: a safe and effective method. Ann Thorac Surg,2002, 73(2):667-670. 被引量:1
  • 7Takakura H, Sasaki T, Hashimoto K, et al. Aortic valve replacement with concomitant annular enlargement for small aortic annulus of less than 19 mm. Ann Thorac Cardiovasc Surg,2000,6(3):190-192. 被引量:1
  • 8Rao V,J Thorac Cardiovasc Surg,1999年,117卷,431页 被引量:1
  • 9Sawant D,Ann Thorac Surg,1997年,63卷,964页 被引量:1
  • 10Tasca G,Brunelli F,Cirillo M,et al.Impact of valve prosthesis-patient mismatch on left ventricular mass regression following aortic valve replacement[J].Ann Thorac Surg, 2005,79(2):505 被引量:1

共引文献16

同被引文献111

引证文献11

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部