针对拉卜楞寺存在的重大火灾隐患,运用调查类比、理论分析、实验对比等手段,对拉卜楞寺火灾危险性进行了系统分析,通过对各种灭火系统灭火有效性的模拟实验,对比分析了不同灭火系统的适用性,提出了灭火系统选型和优化设计方案,为拉卜楞寺重大火灾隐患整改工作提供了参考。
Fire hazards of Labrang Monastery are analyzed systematically and a series of fire suppression experiments with different kinds of systems are performed. Then the applicability of these fire suppression systems in Labrang Monastery is analyzed, and a project of selection and optimal design of fire suppression systems is given. These supply references to the renovation of fire hidden danger in Labrang Monastery.