期刊文献+

Infiniti系统扭动超声对切口温度影响的实验研究 被引量:8

Torsional handpiece of the Alcon Infiniti Vision System: A better option for phacoemulsification surgery
下载PDF
导出
摘要 目的:研究Infiniti Vision System超声乳化仪系统的扭动超声乳化手柄(Ozil)和常规超声乳化手柄(u/s)在白内障手术中对透明角膜切口温度的影响。方法:将40只新鲜的体外猪眼随机分成4组,每组10只,用InfinitiVision System超声乳化仪系统的两种手柄(u/s和Ozil手柄)进行超声乳化手术,分别在堵塞状态和非堵塞状态下,用K型热电偶温度计测定连续状态下脚踏进入3档位,累计时间达0、30、60、90 s时的角膜切口温度。结果:在非堵塞状态和堵塞状态下,当脚踏进入3档位累计时间达30、60、90s时,用Ozil手柄进行手术的角膜切口的平均温度均显著低于常规手柄的温度,差异具有统计学意义(P<0.05)。结论:Infiniti Vision System超声乳化仪系统的扭动超声手柄较常规超声手柄对角膜切口的灼伤更小,更加安全。 Objective: To make a comparative study of the incision temperature in phacoemulsification surgery with the conventional handpiece (u/s) and torsional handpiece (Ozil). Methods: Forty porcine eyes were randomly divided into four groups of equal number, each undergoing phacoemulsification with two different handpieces of the Alcon Infiniti System in occluded and un-occluded states. The wound temperatures at u/s 0 s,30 s,60 s and 90 s were measured and recorded respectively in occluded and unoccluded states with a type k thermocouple digital thermometer. Results: With phaco tips both occluded and un-occluded,the wound temperature measured at u/s 30 s,60 s and 90 s during the surgery with torsional handpiece was significantly lower than that with the conventional handpiece, and the inter-group difference was statistically significant in the two states. Conclusion: Phacoemulsification with the torsional handpiece of the Alcon Infiniti Vision System produces less heat and is thus safer than that with the conventional handpiece in surgical incision.
出处 《医学研究生学报》 CAS 2008年第1期22-24,27,共4页 Journal of Medical Postgraduates
基金 国家自然科学基金资助项目(批准号:30670600)
关键词 扭动超声乳化手柄 切口温度 白内障手术 Torsional handpiece Incision temperature Phacoemulsification surgery
  • 相关文献

参考文献8

  • 1Hoffman RS, Fine IH, Packer M. New phacoemulsification technology [J]. Curr Opin Ophthalmol, 2005,16 ( 1 ) : 38-43. 被引量:1
  • 2Alan Sugar, Robert MS. Clinical course of phacoemulsification wound bums [ J ]. J Cataract Refract Surg, 1999,25 (5) :688-692. 被引量:1
  • 3黄振平.屈光手术的最新技术及其临床应用[J].医学研究生学报,2007,20(4):337-338. 被引量:22
  • 4Liu YZ,Zeng MB ,Liu XL. Torsional mode versus conventional ultrasound mode phacoemulsification [J]. J Cataract Refract Surg, 2007,33 (2) :287-292. 被引量:1
  • 5徐仁凤,黄振平,杨丽萍.白内障术后不同人工晶状体对比敏感度的研究[J].医学研究生学报,2007,20(3):266-268. 被引量:16
  • 6Agarwal A , Agarwal S. Phakonit: phacoemulsification through a 0.9 mm corneal incision [ J ]. J Cataract Refract Surg, 2001,27 (10) :1548-1552. 被引量:1
  • 7Goldblart WS,Finger PT,Perry HD, et al. Hyperthermie treatment of rabbit cornea [ J ]. Invest Ophthalmol Vis Sci, 1989,30 ( 11 ) : 1778-1783. 被引量:1
  • 8Hiroko BM, Shigeto S, Kazuo T. Thermal effect on corneal incision with different phacoemulsification ultrasonic tips [ J ]. J Cataract Refract Surg, 1999,25 ( 1 ) :60-64. 被引量:1

二级参考文献13

  • 1张丽京,王少华,王毅.儿童人工晶体植入术后后囊混浊激光治疗的时机和疗效[J].医学研究生学报,2005,18(11):1022-1024. 被引量:2
  • 2邓小艳,蔡小军,柯治生.白细胞介素-6反义寡核苷酸脂质体预防后发性白内障的初步研究[J].医学研究生学报,2005,18(12):1083-1086. 被引量:2
  • 3Kawesch GM,Kezirian GM.Laser in situ keratomileusis for high myopia with the VISX Star laser[J].Ophthalmology,2000,107 (4):655-661. 被引量:1
  • 4Alio JL,Perez-Santonja JJ,Tervo T,et al.Postoperative inflammation,microbial complications,and wound healing following laser in situ keratomileusis[J].J Refract Surg,2000,16 (5):523-538. 被引量:1
  • 5Ambrosio R Jr,Wilsion SE.Complication of laser in situ keratomileusis:etiology,prevention,and treatment[J].J Refract Surg,2001,17 (3):350-379. 被引量:1
  • 6Binder PS.Flap dimensions created with the Intralase FS laser[J].J Cataract Refract Surg,2004,30 (1):26 -32. 被引量:1
  • 7Maloney RK,Nguyen LH,John ME.Artisan phakic intraocular lens for myopia:short-term results of a prospective,multicenter study[J].Ophthalmology,2002,109:1631-1641. 被引量:1
  • 8Arne JL.Phakic intraocular lens implantation versus clear lens extraction in highly myopic eyes of 30-to 50-year-old patients[J].J Cataract Refract Surg,2004,30(10):2092-2096. 被引量:1
  • 9雄里译.生理光学[M].上海:科学技术出版社,1987:40-81. 被引量:2
  • 10Chmitz S,Dick HB,Krummenauer F,et al.Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation[J].Br J Ophthalmol,2000,84(10):1109-1112. 被引量:1