期刊文献+

BIS和CSI在老年患者异丙酚靶控镇静中的应用 被引量:3

下载PDF
导出
摘要 目的比较在无手术刺激状态下,老年患者靶控输注异丙酚不同镇静程度时,大脑状态指数(CSI)与脑电双频指数(BIS)监测的临床应用价值。方法老年择期手术患者18例,年龄65~78岁,ASAⅠ~Ⅱ级,所行手术不限。全麻诱导前行异丙酚靶控输注(TCI)镇静,靶浓度由0.5μg/ml开始,递增梯度为0.5μg/ml,间隔时间为5min,直至镇静评分(OAA/S)为0后5min停止。试验中,监测并记录患者的CSI、BIS值,间隔20s行OAA/S镇静评分。记录靶控输注系统预测的效应部位浓度值(CE),每变化0.1μg/ml时的数值及时间。结果镇静程度(OAA/S)的变化与CE、BIS、CSI有线性回归关系:与CE呈负相关,与BIS、CSI呈正相关。相关性的程度依次为CE>BIS>CSI。BIS与CSI的监测均能很好地反映患者的镇静程度,但两者对OAA/S变化的相关性无统计学差异。结论随着CE的变化,BIS和CSI可以很好地反映异丙酚对老年患者的镇静程度,CSI的灵敏度更高一些;但是两者对预测体动反应较差。
出处 《江西医药》 CAS 2007年第10期920-922,共3页 Jiangxi Medical Journal
  • 相关文献

参考文献4

  • 1陈勇,佘守章,闫焱,许学兵,许立新.BIS和AEPI监测镇静深度的评价[J].临床麻醉学杂志,2005,21(10):662-664. 被引量:10
  • 2Muravchick S.Anesthesia for the elderly.5ed.In Miller RD,Anesthesia, Philadelphia:Churchill Livingestone.2000.2140 被引量:1
  • 3Kateh T,Suzuki A,Lkedak.Eleetroeneephalographie derivatives as a tool for predicting the depth of the sedation and anesthesia indueed by sevoflurane.Anesthesiology,1998,88:642 被引量:1
  • 4Doi M,Cajraj R J, Mantzaridis H,el al.Relationship between calculated blood concentration of propofol and electrophysiological variable during emergence from anesthesia:comparison of bispectral index,spectral edge frequency and auditory evoked potential index.Br J Anaesth, 1997,78:180 被引量:1

二级参考文献7

  • 1Struys MM, Jensen EW, Smith W, et al. Performance of the ARX-derived auditory evoked potential index as an indicator of anesthetic depth: a comparison with bispectral index and hemodynamic measures during propofol administration. Anesthesiology, 2002,96:803-816. 被引量:1
  • 2Gajraj RJ, Doi M, Mantzaridis H, et al. Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. Br J Anaesth, 1998,80: 46-52. 被引量:1
  • 3Gajraj RJ, Doi M, Mantzaridis H,et al. Comparison of bispectral EEG analysis and auditory evoked potentials for monitoring depth of anaesthesia during propofol anaesthesia. Br J Anaesth,1999,82:672-678. 被引量:1
  • 4Alkire MT. Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers. Anesthesiology,1998,89:323-333. 被引量:1
  • 5Schraag S, Bothner U, Gajraj R, et al. The performance of electroencephalogram bispectral index and auditory evoked potential index to predict loss of consciousness during propofol infusion.Anesth Analg, 1999,89:1311-1315. 被引量:1
  • 6Drummond JC. Monitoring depth of anesthesia: with emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall. Anesthesiology, 2000,93 : 876-882. 被引量:1
  • 7Struys MM, Vereecke H, Moerman A, et al. Ability of the bispectral index, autoregressive modelling with exogenous input-derived auditory evoked potentials, and predicted propofol concentrations to measure patient responsiveness during anesthesia with propofol and remifentanil. Anesthesiology, 2003,99:802-812. 被引量:1

共引文献9

同被引文献6

引证文献3

二级引证文献3

相关作者