期刊文献+

Solid Phase Extraction of Trace Copper(Ⅱ) Using Octadecyl Silica Membrane Disks Modified with N,N′-Disalicylideneethylenediamine

Solid Phase Extraction of Trace Copper(Ⅱ) Using Octadecyl Silica Membrane Disks Modified with N,N′-Disalicylideneethylenediamine
原文传递
导出
摘要 A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by N,N′-disalicylideneethylenediamine (DESDA) and atomic absorption spectrometry was presented. The method is based on complex formation on the surface of the ENVI-18 DISK^TM disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about be 1000 mL providing a preconcentration factor of 500. The maximum capacity of the disks was found to be (389±4) μg for Cu^2+. The limit of detection of the proposed method is 5 ng per liter. The method was applied to the extraction and recovery of copper in different water samples. A simple and reproducible method for the rapid extraction and determination of trace amounts of copper(Ⅱ) ions using octadecyl-bonded silica membrane disks modified by N,N′-disalicylideneethylenediamine (DESDA) and atomic absorption spectrometry was presented. The method is based on complex formation on the surface of the ENVI-18 DISK^TM disks followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effects of potential interfering ions, pH, ligand amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about be 1000 mL providing a preconcentration factor of 500. The maximum capacity of the disks was found to be (389±4) μg for Cu^2+. The limit of detection of the proposed method is 5 ng per liter. The method was applied to the extraction and recovery of copper in different water samples.
作者 MOGHIMI, Ali
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2007年第12期1842-1848,共7页 中国化学(英文版)
关键词 Copper(Ⅱ) solid phase extraction octadecyl slica disks atomic absorption spectrometry N N′-disalicylideneethylenediamine Copper(Ⅱ), solid phase extraction, octadecyl slica disks, atomic absorption spectrometry, N,N′-disalicylideneethylenediamine
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部