期刊文献+

异常炉况下高炉铜冷却壁热态试验与数值模拟 被引量:2

Thermal test and numerical simulation of blast furnace copper stave in abnormal condition
下载PDF
导出
摘要 在高炉铜冷却壁热态试验的基础上,建立铜冷却壁三维模型,模拟高炉正常生产时出现断水、低水速和较高炉气温度等异常炉况时铜冷却壁温度场分布。 A 3 - d model of blast furnace copper stave was established based on the thermal test. Through the simulation, the temperature field of copper stave was obtained in abnormal conditons, such as water - break, low velocity of cooling water and ultrahigh temperature of gas.
出处 《冶金能源》 北大核心 2007年第6期28-30,54,共4页 Energy For Metallurgical Industry
关键词 铜冷却壁 热态试验 数值模拟 异常炉况 copper stave thermal test numerical simulation abnormal condition
  • 相关文献

参考文献6

  • 1BAI Hao, CANG Daqiang, ZONG Yanbing. Experimental Study on Heat Transfer Characteristic of Blast Furnace Copper Stave. Journal of University of Scienee and Technology Beijing, 2002, 9 (4) : 258 -259. 被引量:1
  • 2SHINICHI S. Cast Copper Cooling Stave for Blast Furnace. 2000 Ironmaking Conference Proceedings, 2000, 59:201. 被引量:1
  • 3Robert G., Wolfgang Kowalski, Klaus - Henning Grosspietsch, et al. Copper staves in the blast furnace. Iron and Steel Engineer, 1996, (8) : 30-34. 被引量:1
  • 4Helenbrook, R. G. Cox I. J. and Grundtishch, D. F. Utilization of operational data to improve blast furnace cooling system design. 1983 AISE annual conventional,, (9) : 19 -22. 被引量:1
  • 5ПДЯ ШКеВИЧ АС,Стре Дои КК,Фрейденберг АС.Теплотехнический анализ оптималъного соотношения параметров фугеровки и системы охлаждения шахты доменноя печи.Сга лъ1976,(3):209-213. 被引量:1
  • 6吴懋林,王立民,刘述临.高炉冷却壁和炉衬的三维传热模型[J].钢铁,1995,30(3):6-11. 被引量:28