期刊文献+

高功率因数弧焊逆变电源的整流器设计与实验 被引量:1

Design and experiment of high power factor converter on arc welding inverter power source
下载PDF
导出
摘要 分析了弧焊逆变电源功率因数校正技术的特点,阐述了弧焊逆变电源中基于差接三角形自耦变压器十二脉波整流电路的原理与设计及其功率因数校正机理。通过仿真分析,弧焊逆变电源采用这种电路后,功率因数可以达到99%,电流谐波畸变率降低到7%。实验证明所提方案确实可行。 This paper analyzes the characteristic of the Power Factor Correction (PFC) of arc welding inverter power source, introduces the 12-pulse converter based on delta-type autotransformer connection into arc welding inverter power source ,and its configuration, design scheme and theory on PFC.Simulations confirm that the Power Factor (PF) can be increased to 99%and Total Harmonic Distortion (THD)can be decreased to 7% in arc welding inverter power source using the 12-pulse converter based on delta-type autotransformer connection.The experiment results verify the feasibility of this scheme.
出处 《电焊机》 2007年第11期4-7,共4页 Electric Welding Machine
关键词 弧焊逆变电源 功率因数 多脉波整流 自耦变压器 arc welding inverter power source power factor multi-pulse converter autotransformer
  • 相关文献

参考文献8

二级参考文献24

共引文献15

同被引文献11

  • 1胡明方,雷建华,鲁万华.十二相轴向双分裂整流变压器[J].电工技术,2002(2):11-11. 被引量:1
  • 2Chivite Z,Forsyth F J, A J,et al. Analysis and Practical Evaluation of an 18-pulse Rectifier for Aerospace Appli- cations [C]. Second International Conference on Power Electronics, Machines and Drives. UK, 2004 (1) : 338- 343. 被引量:1
  • 3Meng Fangang,Yang Wei and Yang Shiyan. Effect of volt- age transformation ratio on the kVA rating of delta-con- nected autotransformer for 12-pulse rectifier system [J]. IEEE transactions on industry applications,2013,60 (9): 3579-3588. 被引量:1
  • 4Kamath G R,Runyan B,Wood R. A Compact Autotrans-former Based 12-pulse Rectifier Circuit [C]. Industrial Electronics Society,the 27th Annual Conference of the IEEE, 2001 (2) : 1344-1349. 被引量:1
  • 5Singh B,Singh B N,Chandra A,et al. A review of three- phase improved power quality AC-DC converters [J]. IEEE transactions on industry applications,2004,51 (3): 641-660. 被引量:1
  • 6Wang Weimin,Cheng K W E,Ding K,et al. A Novel ap- proach to the analysis of the axial-flux permanent-magnet generator with coreless stator supplying a rectifier load[J]. IEEE Transactions on Magnetics,2011,47 (10):2391- 2394. 被引量:1
  • 7Maehesh S,Tsuneo J K,Noriyuki T. A hybrid 18-Pulse Rescheme for Diode Front end Variable Frequency Drives [ C ]//Energy Conversion Congress and Exposition (ECCE), IEEE 2009,2009 : 1562-1568. 被引量:1
  • 8Wu Xinke,Xie Xiaogao,Zhao Chen,et al. Low voltage and current stress ZVZCS full brigdge DC-DC converter using center tapped rectifier reset [J ]. IEEE Transactionson Industrial Electronics, 2008,55 (3) : 1470-1477. 被引量:1
  • 9Kocman S,Kolar V,Trung V T. Elimination of Harmonics Using Multi-Pulse Rectifiers[C]//Harmonics and Quality of Power (ICHQP). 14th International Conference, 2010 : 1-6. 被引量:1
  • 10Bhim S, Sanjay G, Ambrish C,et al. Multi-pulse AC-DC Converters for Improving Power Quality :A Review [C ]. IEEE Transactions on Power Electronics, 2008,23 : 260- 289. 被引量:1

引证文献1