期刊文献+

C臂X线透视下分步引导上中胸椎椎弓根螺钉安全植入实验研究 被引量:1

Stepwise implantation of pedicle of upper-middle thoracic vertehral arch screws under guidance of C-shaped X-ray fluoroscopy:an experimental study
下载PDF
导出
摘要 目的探索一种能术中监测并引导上中胸椎椎弓根螺钉安全植入的简单、经济、确实可行的方法。方法第一步:取6具正常成人T1~T8脊椎骨架标本,分解出单个椎体,导针沿椎弓根轴线进入,分别于进针点及针前端位于椎弓根中部、椎体后缘及椎体前缘皮质下,C臂X线透视记录、分析椎弓根轴线导针在进针点及不同进针深度时在正侧位透视图像上导针前端的位置,并推断出相关位置对应关系变化规律。第二步:根据第一步所得椎弓根轴线导针位置变化规律进行上中胸椎椎弓根螺钉植入。取6具T1~T8脊柱标本,C臂X线机引导分步植入椎弓根螺钉96枚,然后作CT检查,判定椎弓根螺钉位置。根据CT检查结果,判定C臂X线透视分步引导椎弓根螺钉植入的安全性及准确性,分为优(椎弓根螺钉安全位于椎弓根内)、可(螺钉穿破椎弓根内或外侧骨皮质较少,突破在2mm以内)、差(螺钉穿破椎弓根内外骨皮质较多,突破在2mm以上)3个等级。结果优90枚(93.8%),可6枚(6.2%)。结论C臂X线透视下分步引导上中胸椎椎弓根螺钉植入是一种简单、经济、确实可行的方法,具有安全、准确和实用特点。 Objective To explore a simple, practical and safe way of implanting pedicle of upper-middle thoracic vertebral arch screws under X-ray guidance, Methods First, 6 normal adult thoracic spine samples(T1 - T8) were selected, horn which single spine units were separated. A surgical probe went in along the pedicle axis. The C-shaped arm X-ray recorded the four probe positions: at the entering point, the front end of the probe in the middle of the pedicle, at the pack of the spine, and under the cortex of the front of the spine. The position of the front end of the probe at the entering point, and the front end of the probe at different depth at central-side perspective position were analyzed. The related positions and their corresponding changes Were also analyzed. Second, based on the changes mentioned above, different steps were adopted under the guidance of the C-shaped arm X-ray, to safely implant upper-middle thoracic pedicle screws. First, 6 T1-T8 spine samples were used, and under the guidance of the C-shaped arm device, 96 pedicle screws were implanted. After the operation, the spine samples were scanned through CT, and the positions of the screws were determined. According to the result of the CT scanning, the safety and accuracy of the implantation were evaluated as excellent (the screw was safely inside the pedicle); good (the screw penetrated a little of the inside or outside bone cortex, within 2mm.) and failure (the screw penetrated a lot, more than 2mm). Results Ninety screws (93.8%) were evaluated as excellent, 6 (6.2%) were good and there was no failure. Conclusion The implantation of upper-middle thoracic pedicle screw under the guidance of the C-shaped arm X-ray fluoroscopy is a simple and feasible method characterized by its safety, accuracy and practicability.
出处 《浙江医学》 CAS 2007年第10期1054-1056,1108,共4页 Zhejiang Medical Journal
关键词 C臂X线透视 上中胸椎 胸椎椎弓根螺钉 安全植入 C-shaped arm X-ray perspective Upper-middle thoracic pedicle Pedicle screw Safe implantation
  • 相关文献

参考文献13

二级参考文献38

  • 1Kim YJ, Lenke LG, Cho SK, et al. Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis. Spine 2004; 29 ( 18 ) : 2040 - 8 被引量:1
  • 2Parent S, Labelle H, Skani W, et al. Thoracic pedicle morphometry in vertebrae from scoliotic spines. Spine 2004; 29(3): 239 -48 . 被引量:1
  • 3Lee SM, Suk SI, Chung ER. Direct vertebral rotation: a new techmque of three-dimensional deformity correction with segmental pedicle screw fixation in adol t idiopathic scoliosis. Spine. 2004 ;29(3): 343 -9 被引量:1
  • 4Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal, deformities: are they really safe? Spine 2001;26 (18):2049- 57 被引量:1
  • 5Datir SP, Mitra SR. Morphometric study of the thoracic vertebral pedicle in an Indian population. Spine 2004; 29( 11 ): 1174 - 81 被引量:1
  • 6Parent S, Labelle H. Skalli W, et al. Morphometric analysis of anatomic scoliotic specimens. Spine 2002; 27 (21 ) : 2305 - 11 被引量:1
  • 7Liljenqvist UR, Link TM, Halm HI". Morphometnc analysts ot thoractc and lumbar vertebrae in idiopathic scoliosis. Spine 2000; 25(10): 1247 -53 被引量:1
  • 8O'Brien MF, Lenke LG, Mardjetko S, et al. Pedicle morphology in thoracic adolescent idiopathic scoliosis: is pedicle fixation an anatomically viable technique? Spine 2000; 25(18) :2285 - 93 被引量:1
  • 9Kim YJ, Lenke LG, Bridwell KH, et al. Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 2004; 29(3): 333 -42 被引量:1
  • 10Polly DW Jr, Potter BK, Kuklo T, et al. Volumetric spinal, canal, intrusion: a comparison between thoracic pedicle screws and thoracic hooks. Spine 2004; 29(1):63-9 被引量:1

共引文献338

同被引文献6

引证文献1

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...