摘要 对若干钛钢混合结构换热器与冷却器耐腐蚀失效事例进行了讨论,其腐蚀原因应多方面综合考虑,应重视材料选用、结构设计、焊接质量与设备管理等。  The reasons of corrosion failures in several heat exchangers made by titanium and steel mixed structured are discussed in this article. The corrosion should consider from many different aspects comprehensively. The selection and application of materials, the design of structure, the welding quality and the management of equipment should be paid attention in the corrosion control to the heat exchangers.
作者 余存烨
出处 《全面腐蚀控制》 2007年第5期4-7,共4页 Total Corrosion Control
关键词 钛钢 混合结构 换热器 腐蚀 titanium and steel mixed structure heat exchanger corrosion