期刊文献+

超声编码激励功率M型多普勒栓子检测的实验研究

An experimental study on ultrasound emboli detection using coded excitation power M-mode Doppler
下载PDF
导出
摘要 超声栓子检测对于研究和预防缺血性脑卒中具有重要的意义。功率M型多普勒(power M-mode Doppler,PMD)在全面直观地反映栓子运动方面具有很大的优势,但如果采用传统的长脉冲激励方法,则在检测灵敏度与距离分辨率方面就存在一定的缺陷。本文从超声栓子检测原理出发,采用编码激励方法改善PMD栓子检测效果,并在设计搭建的实验平台上研究了编码激励PMD栓子检测的性能。实验结果验证了理论分析的结论,得出编码激励有利于提高PMD栓子检测的轴向分辨率和提高栓子与背景血流信号的能量比。 Ultrasound emboli detection plays an important role in the study and prevention of isehemie stroke. Power M-mode Doppler (PMD) has great advantages in intuitive and comprehensive display of emboli behavior. However, by using traditional long pulse excitation, the tradeoff between sensitivity and axial resolution compromises the performance of PMD. Based on the principle of ultrasound emboli detection, the method using coded excitation PMD is introduced and studied on the designed experimental platform. The conclusion from theoretical analysis is demonstrated by the experiment results that the axial resolution and measured emboli-to-blood power ratio can be increased by applying coded excitation in PMD.
作者 赵珩 高上凯
出处 《北京生物医学工程》 2007年第5期475-479,共5页 Beijing Biomedical Engineering
关键词 编码激励 功率M型多普勒 栓子检测 coded excitation power M-mode Doppler emboli detection
  • 相关文献

参考文献6

  • 1Aaslid R, Markwalder T, Nornes H. Noninvasive transcranial Doppler ultrasound recording of flow - velocity in basal cerebral arteries[J]. Journal of Neurosurgery, 1982, 57 : 769 - 774 被引量:1
  • 2Evans DH. Ultrasonic detection of cerebral emboli. Ultrasonics Symposium. 2003, 316 -326 Evans DH. Ultrasonic detection of cerebral emboli [ C ]. Ultrasonics Symposlum,2003 : 316 - 326 被引量:1
  • 3Smith JL, Evans DH, Fan L,et al. Differentiation between emboli and artifacts using dual - gated transcranial Doppler ultrasound[J]. Ultrasound in Medicine & Biology,1996, 22:1031 - 1036 被引量:1
  • 4Moehring MA, Spencer MP. Power M - mode Doppler (PMD) for observing cerebral blood flow and tracking emboli [ J ]. Ultrasound in Medicine & Biology,2002, 28( 1 ) : 49 -57 被引量:1
  • 5Moehring MA, Klepper JR. Pulse Doppler ultrasound detection, characterization and size estimation of emboli in flowing blood [J]. IEEE Transactions in Biomedical Engineering, 1994, 41: 35 - 44 被引量:1
  • 6Chiao RY, Hao X. Coded excitation for diagnostic ultrasound: a system developer's perspective [J]. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, 2005, 52:160 - 170 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部