摘要
振动是给水泵经常遇到的故障,动平衡是现场消除泵振动的常用手段,以某电厂多台给水泵振动的诊断与处理为例,详细的介绍了若干给水泵的动平衡试验,对给水泵动平衡工作需要注意的一些事项进行总结,为给水泵振动的处理提供参考。
Vibration is a major fault of feet water pump. Dynamic balancing is the primary means to eliminate the vibration. The paper takes diagnosis and treatment of some feed water pump's vibration in one power plant as example and detailedly introduces some dynamic balancing and summarizes matters during test of feed water pump, which is useful for the further treatment of feed water pump vibration.
出处
《电站辅机》
2007年第3期37-39,共3页
Power Station Auxiliary Equipment
关键词
振动
给水泵
故障诊断与处理
动平衡
vibration
feed water pump
fault diagnosis and treatment
dynamic balance