摘要
目的:使用MP妊高征监测仪对妊高征进行预测并干预,以降低妊高征发生率。方法:应用妊高征监测仪对1100例孕18-41周的孕妇进行预测和干预,动态观察效果。结果:预测阳性率达30.5%,对预测阳性者进行干预,使妊高征发病率由26.9%降至8.6%。结论:应用妊高征监测系统对妊高征早期预测并干预,是降低妊高征发生率的有效措施之一。
Objective: To predict, screen and interfere PIH by non - invasive MP and to decrease the morbidity of PIH. Methods: MP was used to predict and interfere 1 100 pregnant women at 18-41 weeks of gestation and to observe the effect dynamiely. Results: The positive rate was up to 30. 5% and the morbidity of PIH was lowered from 26. 8% to 8. 6% through interfering the positive cases. Conclusion: MP system can predict, observe, interfere therapeutic effect early and decrease the morbidity of PIH effectively.
出处
《中国妇幼保健》
CAS
北大核心
2007年第28期3942-3943,共2页
Maternal and Child Health Care of China
关键词
妊高征
脉搏波
预测
干预
PIH
Pulse wave
Predict and interference