期刊文献+

300MW机组制粉系统耗电率高的原因分析及对策 被引量:2

Analysis and Countermeasure of High Power Consumption Rate of Coal Powder System in 300 MW Capacity Units
下载PDF
导出
摘要 广东粤华发电有限责任公司5号锅炉制粉耗电率偏高,导致发电成本上升,且不符合当今全社会开展节能降耗行动的要求。通过试验、分析,找出了原因,采取了改进措施,使制粉电耗降低。 The high power consumption rate of coal powder system of No. 5 generating unit in Guangdong Yuehua Power Company Ltd. causes high generating electricity cost, and misfits requests of reducing energy consumption in development progress. The main problems and its solu- tion in regard with economic operation of reducing power consumption rate of coal powder system in the fossil fuel power station are pointed out through many experiments.
作者 梁建超
出处 《锅炉技术》 北大核心 2007年第5期54-55,78,共3页 Boiler Technology
关键词 制粉系统 耗电率 原因 对策 coal powder system power consumption rate problem analysis cduntermeasure
  • 相关文献

参考文献3

  • 1上海锅炉厂.石洞口电厂1025t/h亚临界压力直流锅炉产品设计说明书[R].上海:石洞口发电厂,1987. 被引量:1
  • 2樊泉桂..锅炉原理[M],2004.
  • 3冯国强,黄家洲,等.广东粤华发电有限责任公司300MW机组直流锅炉运行规程[R].广州:广东粤华发电有限责任公司,2000. 被引量:1