期刊文献+

细水雾灭火系统技术经济性分析 被引量:8

Technical economy analysis of water mist extinguishing systems
下载PDF
导出
摘要 以某银行消防系统改造工程项目为例,比较了细水雾灭火系统和七氟丙烷气体灭火系统的材料设备造价和施工维护费用。从经济造价的角度,探讨细水雾灭火系统在实际工程应用中替代气体灭火系统的可能。并给出了细水雾灭火系统应用于实际工程的一些建议。 Taking a bank fire-extinguishing system renovation project as an example,the engineering costs of mist fire extinguishing systems and HFC-227ea systems were compared in this paper,including the cost of material and equipment,the cost of construction and maintenance.The comparison results helped to evaluate the economical feasibility of mist substituting for HFC-227ea.Besides,some suggestions were given on the practical engineering application of mist systems.
出处 《消防科学与技术》 CAS 2007年第5期542-544,共3页 Fire Science and Technology
基金 国家标准<细水雾灭火系统技术规范>制订项目
关键词 细水雾灭火系统 七氟丙烷灭火系统 经济分析 mist fire extinguishing systems HFC-227ea systems economic analysis
  • 相关文献

参考文献4

二级参考文献20

  • 1周华,邓东,周善淮,范垣宵,杨华勇.高压单相流细水雾灭火系统研制及实验研究[J].消防科学与技术,2004,23(4):351-353. 被引量:8
  • 2Sung Chan Kim,Hong Sun Ryou.An experimental and numerical study on fire suppression using a water mist in an enclosure[J].Building and Environment,2003,(38):1309-1316. 被引量:1
  • 3Hiroshi Shimizu,Manai Tsuzuki,Yasuo Yamazaki,A Koichi Hayashi.Experiments and numerical simulation on methane flame quenching by water mist[J].Journal of Loss Prevention in the Process Industries,2001,(14):603-608. 被引量:1
  • 4Kuldeep Prasad,Gopal Patnaik,K Kailasanath.A numerical study of water-mist suppression of large scale compartment fires[J].Fire Safety Journal,2002,(37):569-589. 被引量:1
  • 5J H Ferziger.Large eddy simulation[D].Simulation and Modeling of Turbulent Flows,New York:Oxford University Press,1996. 被引量:1
  • 6GB50219-95.水喷雾灭火系统设计规范[S].[S].,.. 被引量:39
  • 7NFPA750-1996,Standard on water mist Fire protection systems[S]. 被引量:1
  • 8Back G,Lattimer B,Beyler C.Full-scale testing of water mist fire suppression systems for small machinery spaces and spaces with combustible boundaries.volume[R].1999. 被引量:1
  • 9杨立军 蔡国飙 刘洪山.哈龙替代产品-超细气水雾灭火系统技术报告 北京市科委248工程-保护臭氧层工程验收报告[R].,2004.. 被引量:1
  • 10Herterich O.Water as an extinguishing agent,Heidelberg:Alfred Hüthig Publishing Company,1960. 被引量:1