摘要 介绍了关节坐标测量机原理、组成,并对其进行了误差分析。从理论上分析了圆光栅安装偏心误差对测量结果的影响,介绍了圆光栅分度误差测量方法,并采用非线性拟合的方法对该项误差进行了修正。 The paper introduces the principles and components of the multi-joint CMM, and does the error analysis. It also analyzes the influence of the eccentricity error of the circular optic grating installation on the results, and introduces the measuring method of graduation error. This error has been corrected by the non-linearity fitting.
出处 《计测技术》 2007年第4期41-43,69,共4页 Metrology & Measurement Technology
关键词 坐标测量机 关节 误差修正 圆光栅 CMM joints error correction circular optic grating
  • 相关文献

参考文献7

  • 1汪平平,费业泰,林慎旺.柔性三坐标测量臂的标定技术研究[J].西安交通大学学报,2006,40(3):284-288. 被引量:31
  • 2张国雄..三坐标测量机[M],1999.
  • 3费业泰主编..误差理论与数据处理 第5版[M].北京:机械工业出版社,2005:205.
  • 4王霞..智能关节式坐标测量机数据采集系统的研制[D].合肥工业大学,2006:
  • 5Denavit J,Hartenberg R S.A kinematic notation for lower pair mechanisms based on matrices[J].ASME Journal of applied mechanics.1955,22(2):215-221. 被引量:1
  • 6叶东..多关节坐标测量机的理论和技术[D].哈尔滨工业大学,1999:
  • 7Renishaw Inc.The accuracy of angle encoders,technical article from the encoder products division[EB/OL].http://www.renishaw.com/userfiles/acrobat/ukengilsh/l-p517-9120.pdf. 被引量:1

二级参考文献14

  • 1周学才,张启先.距离误差模型在机器人精度研究中的应用[J].机器人,1995,17(1):1-6. 被引量:23
  • 2小美浓武久,はが.多关节型三次元测定机精度向上[J].精密工学会志,1986,52(8):1300-1304. 被引量:1
  • 3Werner L.Scanmax-a novel 3D coordinate measuring machine for the shop-floor environment[J].Measurement,1996,18(1):17-25. 被引量:1
  • 4Brank K,Miomir V.Calibration and accuracy of manipulation robot models-an overview[J].Mech Mach Theory,1994,29(3):479-500. 被引量:1
  • 5Roth S,Mooring B W,Ravani B.An overview of robot calibration[J].IEEE Journal of Robotics and Automation,1987,RA-3(5):377-385. 被引量:1
  • 6Mooring B W,Padavala S S.The effect of kinematics model complexity on manipulator accuracy[A].IEEE International Conference on Robotics and Automation[C].Scottsdale,Arizona:IEEE,1989.593-598. 被引量:1
  • 7Kyle S A.Optical methods for calibrating and inspecting robots[J].Computing and Control Engineering Journal,1995,6(4):166-173. 被引量:1
  • 8吴汉欣 张启先 郑时雄.关节式三坐标测量机系统误差的补偿及其实验[J].机器人,1988,2(5):50-54. 被引量:5
  • 9Tang Geo-Ry,Liu Lu-Sin.Calibration methods based on flat surfaces[J].Mech Mach Theory,1994,29(2):195-206. 被引量:1
  • 10Vira N.Spherical coordinate automatic measurement system for robots' end-point sensing[J].Precision Engineering,1989,11(3):151-164. 被引量:1

共引文献30

同被引文献76

引证文献11

二级引证文献182

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部