摘要
无除氧器热力系统可使回热系统得到简化,并提高其可靠性及经济性。针对国产200MW汽轮机制定了三种无除氧器热力系统原则性方案,并对各方案的经济性进行了详细计算分析。在进行了综合研究后,作出了方案选择。
Thermodynamic system without deaerator helps simplify the regenerative subsystem and improves its reliability and economics.In view of domestically made 200MW steam turbine,three principled schemes of thermodynamic system without deaerator have been draft up,with detail calculation and analysis of economics of various schemes carried out.The scheme selection is made after comprehensive study and some key technical problems are preliminarily studied.
出处
《中国电力》
CSCD
北大核心
1997年第3期35-40,共6页
Electric Power
关键词
蒸汽透平
热力系统
加热器
thermodynamic system without deaerator scheme selection mixed type heater water level regulation and protection selection of pumps