期刊文献+

西安脉冲堆热柱孔道中子束流参数测量 被引量:1

Parameter Measurement of Thermal Neutron Beam in Thermal Column of Xi’an Pulse Reactor
下载PDF
导出
摘要 采用飞行时间法测量了西安脉冲堆热柱孔道热中子束流中子能谱分布,能谱测量结果较Thermal Maxwellian理论谱偏软,中子谱平均能量为0.042±0.01eV。采用金箔活化法测得热柱孔道出口前端热中子注量率为1.18×105 cm-2.s-1,热中子注量率测量的不确定度为3%。 The distribution of the neutron spectra in the thermal column of Xi'an pulse reactor was measured with the time of flight method in this paper. Comparing with the thermal Maxwellian theory neutron spectra, the thermal neutron spectra measured in experiment is a little softer, and the average neutron energy in measurement spectra is about 0.042+0.01eV. The thermal neutron fluence rate at the front end of the thermal column, preliminarily measured with gold foil activation techniques, is about 1.18×10^5 cm^-2·s^-1. The standard uncertainty of the measured thermal neutron fluence is about 3%.
出处 《核动力工程》 EI CAS CSCD 北大核心 2007年第4期1-4,共4页 Nuclear Power Engineering
关键词 热中子能谱 热中子注量率 反应堆 飞行时间法 活化法 Thermal neutron spectra, Thermal neutron fluence rate, Reactor, Time of flight method, Activation method
  • 相关文献

参考文献4

  • 1复旦大学等编..原子核物理实验方法 下[M].北京:原子能出版社,1982:371.
  • 2陈敏衡,丛德滋,方图南.化工原理(下册)[M].北京:化学工业出版社,1997:213. 被引量:2
  • 3越骞.用^235U裂变电离室绝对测量热柱中子注量率:硕士论文[D].北京:中国原子能科学研究院,1984-14. 被引量:1
  • 4Berg S,Mce Groy W N.A Computer-Automated Iterative Method for Neutron Flux Spectra Determination by Foil Activation[R].Atomic International Tech.Rep.,AFWLTR-67-41,1967. 被引量:1

共引文献1

同被引文献9

  • 1LOCHE R G L. Biological effects and therapeu- tic possibilities of neutrons[J]. American Journal of Roentgenology, 1936, 36: 1-13. 被引量:1
  • 2BRAMBLETT R L, EWING R I, BONNER T W. A new type of neutron spectrometer[J]. Nucl Instrum Methods, 1960, 9: 1-12. 被引量:1
  • 3ALEVRA A V, THOMAS D J. Neutron spec- trometry in mixed fields: Multisphere spectrome ter[J]. Radiat Prot Dosi, 2003, 107(1-3): 37 72. 被引量:1
  • 4WIEGEL B, ALEVRA A V, SIEBERT B R L. Calculations of the response functions of bonner spheres with a spherical 3 He proportional counter using a realistic detector model, PTB-N-21[R]. Germany: PTB, 1994. 被引量:1
  • 5REGINATTO M, GOLDHAGEN P. MAXED: A computer code for the deconvolution of multi- sphere neutron speetrometer data using the maxi mum entropy method, EML-595[R]. USA: US DOE, 1998. 被引量:1
  • 6ISO 8529 1:2001 (E).Reference neutron radia tions, Part 1: Characteristics and methods of production[S]. Geneva, Switzerland: Interna- tional Organization for Standardization, 2001. 被引量:1
  • 7ROBERTS N J, PARFITT M J. MCNPX rood eling of the NPL manganese bath facility based on a converted CAD model[J]. Radiation Meas urements, 2010, 45(10): 1 346-1 349. 被引量:1
  • 8ING H, CLIFFORD T, MCLEAN T, et al. ROSP[C] A simple reliable high resolution neu- tron spectromete.r[J]. Radiat Prot Dosi, 1997, 70(1-4) : 273-278. 被引量:1
  • 9陈军,李春娟,宋明哲,李玮,姚顺和,刁立军,姚艳玲,张紫竹,高集金,张瀷凡.BNCT医院中子照射器辐射场特性参数初步测量[J].中国工程科学,2012,14(8):106-112. 被引量:5

引证文献1