摘要
本文介绍了残肢表面形状测量系统结构参数的校正分析和校正实验。作为验证,并用校正后的系统对平板进行了测量,测量数据很好。通过对测量数据的分析给出了系统的工作距离、有效视场和重建精度之间的关系。
This paper present the camera calibration and the projector calibration of measurement system for surface of the stump and some related experiments. As a verification, a plate covered with white paper was measured with the calibrated system, and the experimental results were excellent. After data analysis, the relation was given among the work distance, the effective view field and the reconstruction accuracy of the prototype instrument.
出处
《中国生物医学工程学报》
EI
CAS
CSCD
北大核心
1997年第2期147-153,共7页
Chinese Journal of Biomedical Engineering
关键词
假体
摄象机定标
机器视觉
假肢
Prosthetics and orthotics
Camera calibration
Machine vision