介绍了交联电缆生产线立塔的结构设计,该立塔属于B级高度的钢筋混凝土高层建筑结构,针对其结构特点,在结构选型、结构布置、结构计算和构造措施等方面进行了详细的探讨,通过方案对比,采用巨型框架结构,很好地满足了规范和使用的要求。
This paper presents the structure design of a high-rise building in detail, which is a tower workshop of product line of cable. The building is a high-rise building with B.grade height. We use effective measures to meet with its structural characters by bodily form choosing, structure plane arrangement, structure computing and some structural measures. According to contrast of examples, the mega frame structure can well satisfy the code and the use demand.
出处
《山西建筑》
2007年第21期83-84,共2页
Shanxi Architecture
关键词
高耸结构
高宽比
轴压比
构造措施
延性
high-rise building, height-to-width ratio, axial compression ratio, structural measures, ductility