介绍了云浮发电厂2号发电机定子A相18槽线棒冷却水流量偏小缺陷的检查方法和处理过程。将堵塞线棒更换后,该槽层间线圈温度下降,发电机运行正常。
The inspection method and handling process of lower cooling water flow rate defect in winding bars of slot no. 18 in stator' s phase A of generator no. 2 in Yunfu Power Plant have been presented. After replacement of the clogged winding bars, the coil temperature in the said slot has decreased, and the operation of generator to be normal.