摘要 应用厌氧—混凝工艺进行造纸中段废水处理实验,实验表明最佳实验条件是:厌氧反应器反应温度为35℃,HRT为32h,水力负荷为0.8m3/m2·d。混凝实验混凝剂为硫酸铝,pH控制在5.23,投加量为100mg/L。在最佳实验条件下,经该工艺处理后废水的CODCr、色度从981.8mg/L、128倍分别降至68.1mg/L、8倍,原水SS为202mg/L时,出水中未检出SS,主要指标均满足《污水综合排放标准》GB8978-1996一级标准的要求。 The anaerobic-coagulation process was used to treat the pulp mid-term wastewater. It is shown that the optimum conditions are as following: the temperature of anaerobic reactor is 35℃, the HRT are 32 hours, and the hydraulic load is 0.8 m^3/m^2·d. The coagulant is aluminum sulfate, the optimal pH is 5.23, the optimal dosage is 100 mg/L. At optimum conditions, the CODCr, colourity and SS of the pulp mid-term wastewater treated by anaerobic-coagulation process were reduced from 981.8 mg/L, 128 times, 202 mg/L to 68.1 mg/L, 8 times, 0 mg/L, respectively. The quality of the effluent can satisfy the first class in Integrated Wastewater Discharge Standard.
出处 《净水技术》 CAS 2007年第3期54-56,共3页 Water Purification Technology
基金 广西区教育厅科研项目(编号:桂教科研2003-22-1) 广西高校百名中青年学科带头人资助计划项目(编号:桂教人2003-97)
关键词 厌氧 混凝 造纸中段废水 anaerobic treatment coagulation pulp mid-term wastewater